Transesophageal Doppler echocardiography evaluation of coronary blood flow velocity in baseline conditions and during dipyridamole-induced coronary vasodilation.

Author:

Iliceto S1,Marangelli V1,Memmola C1,Rizzon P1

Affiliation:

1. Division of Cardiology, University of Bari, Italy.

Abstract

Transesophageal echocardiography allows the evaluation of proximal coronary artery anatomy and coronary blood flow velocity (CBFV). To assess the potential of transesophageal echocardiography in evaluating CBFV and its variations induced by coronary-active drugs, we studied 15 patients by high-quality pulsed wave Doppler recordings of CBFV. In these patients, transesophageal Doppler evaluation of CBFV was performed before, 2 minutes after cessation of dipyridamole infusion (0.56 mg/kg in 4 minutes), and 2 minutes after aminophylline infusion (240 mg injected 4 minutes after cessation of dipyridamole infusion). The following CBFV parameters were evaluated at each of the three steps of the study protocol: maximal and mean diastolic velocities and maximal and mean systolic velocities. Furthermore, the following indexes of coronary flow reserve were evaluated: the ratio between maximal diastolic velocity recorded after and before dipyridamole administration and the ratio between mean diastolic velocity recorded after and before dipyridamole administration. Nine of the 15 patients had a normal left anterior descending coronary artery (group A), whereas the remaining six had significant (less than or equal to 75%) stenosis (group B). In group A patients, all CBFV parameters increased significantly during dipyridamole infusion and returned to near baseline values after aminophylline infusion. In group B patients, on the other hand, none of the CBFV parameters increased after dipyridamole infusion. Dipyridamole/baseline maximal diastolic velocity and mean diastolic velocity ratios were, respectively, 3.22 +/- 0.96 and 3.04 +/- 0.88 in group A and 1.46 +/- 0.45 (p less than 0.01 versus group A) and 1.48 +/- 0.49 (p less than 0.01 versus group A) in group B patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3