The diastolic hyperemic flow versus pressure relation. A new index of coronary stenosis severity and flow reserve.

Author:

Mancini G B1,McGillem M J1,DeBoe S F1,Gallagher K P1

Affiliation:

1. Department of Internal Medicine, University of Michigan Medical School, Ann Arbor.

Abstract

The measurement of coronary flow reserve, traditionally calculated as the ratio of maximal hyperemic blood flow divided by basal flow, is difficult to interpret in serial studies because fluctuating hemodynamic parameters may affect either basal or hyperemic flow measurements. To determine the magnitude of this problem and to develop alternative approaches for measuring vascular reserve, 10 anesthetized dogs were instrumented with aortic and inferior vena cava occluders, electromagnetic coronary flow probes, and high-fidelity micromanometers in the left ventricle and aortic root. Coronary flow was measured in the basal state and during maximal hyperemia induced by a steady-state adenosine infusion. Observations were made in the absence of a stenosis and in the presence of two incremental degrees of subcritical stenosis produced by a rigid, external screw occluder. Several parameters of vascular reserve were determined: 1) coronary flow reserve (defined above), 2) mean hyperemic flow divided by mean aortic pressure, 3) mean hyperemic flow divided by the difference between mean aortic pressure and left ventricular end-diastolic pressure, and 4) the slope of the instantaneous relation between diastolic hyperemic flow versus pressure. Each parameter was measured during five steady-state pressure levels achieved by partial occlusion of either the inferior vena cava or the aorta and the levels ranged from 82 +/- 8 mm Hg (mean +/- SD) to 127 +/- 9 mm Hg during hyperemia. All measures of vascular reserve were found to be dependent on hemodynamic parameters such as heart rate and mean aortic pressure. The slope of the instantaneous relation between diastolic hyperemic flow and pressure, however, showed only minimal dependence on heart rate and, in contrast to coronary flow reserve measurements, distinguished between the normal and the two stenotic states. Further, this optimal performance of the hyperemic flow versus pressure slope index was shown in a model in which coronary flow and myocardial work were not independently controlled. This index provides a sensitive and reliable indication of subcritical stenosis severity that may have clinical applications.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3