Effectiveness of recombinant desulphatohirudin in reducing restenosis after balloon angioplasty of atherosclerotic femoral arteries in rabbits.

Author:

Sarembock I J1,Gertz S D1,Gimple L W1,Owen R M1,Powers E R1,Roberts W C1

Affiliation:

1. University of Virginia Health Sciences Center, Department of Medicine, Charlottesville 22908.

Abstract

BACKGROUND The effectiveness of balloon angioplasty is limited by a restenosis rate of approximately 30%. Recombinant desulphatohirudin (r-hirudin [CGP 39393]) has been found to be highly effective in preventing acute platelet-rich thrombosis after deep arterial injury as compared with heparin. METHODS AND RESULTS This study evaluated the effect of intravenous r-hirudin, a selective inhibitor of thrombin, on restenosis after balloon angioplasty in 29 rabbits. Focal femoral atherosclerosis was induced by air desiccation endothelial injury followed by a 2% cholesterol diet for 1 month. At angioplasty (2.5-mm balloon with three 60-second, 10-atm inflations 60 seconds apart), the rabbits received heparin (150 units/kg bolus, n = 16) or r-hirudin (1 mg/kg bolus followed by infusions of 1 mg/kg for the first hour and 0.5 mg/kg for the second hour, n = 13). Angiograms performed before and after angioplasty and before death were analyzed quantitatively by a blinded observer. Rabbits were killed 2 hours (n = 14) or 28 days (n = 15) after angioplasty. Femoral arteries were fixed in situ by perfusion of 10% formaldehyde at 100 mm Hg. The mean luminal diameter of the arteries with successful angioplasty (greater than or equal to 20% increase in luminal diameter) in rabbits treated with heparin (n = 8 arteries) increased from 1.18 +/- 0.29 mm before angioplasty to 1.86 +/- 0.24 mm immediately after angioplasty (p less than 0.001) and decreased to 0.94 +/- 0.69 mm (p = 0.0004) at 28 days after angioplasty. In rabbits treated with r-hirudin (n = 11 arteries), the mean luminal diameter increased from 1.14 +/- 0.17 mm before angioplasty to 1.68 +/- 0.20 mm immediately after angioplasty (p less than 0.001) and decreased to 1.37 +/- 0.47 mm (p = 0.01) at 28 days after angioplasty. The mean reduction in luminal diameter by angiography was less in the r-hirudin-treated group than in the heparin-treated group (0.30 +/- 0.33 versus 0.92 +/- 0.61 mm, p = 0.01). Blinded planimetric analysis of stained histological sections of the femoral arteries also showed less cross-sectional area narrowing by plaque in rabbits treated with r-hirudin compared with those treated with heparin (22 +/- 16% verus 48 +/- 29%, p = 0.01). Both groups had similar numbers of arteries with histological evidence of balloon-induced plaque tear (12 of 13 versus 13 of 15). CONCLUSIONS Rabbits receiving r-hirudin at the time of experimental balloon angioplasty had significantly less restenosis by angiography and by quantitative histopathology than rabbits receiving heparin.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 228 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3