Noninvasive quantification of regional myocardial blood flow in coronary artery disease with oxygen-15-labeled carbon dioxide inhalation and positron emission tomography.

Author:

Araujo L I1,Lammertsma A A1,Rhodes C G1,McFalls E O1,Iida H1,Rechavia E1,Galassi A1,De Silva R1,Jones T1,Maseri A1

Affiliation:

1. MRC Cyclotron Unit, Hammersmith Hospital, London, UK.

Abstract

BACKGROUND Oxygen-15-labeled water is a diffusible, metabolically inert myocardial blood flow tracer with a short half-life (2 minutes) that can be used quantitatively with positron emission tomography (PET). The purpose of this study was to validate a new technique to quantify myocardial blood flow (MBF) in animals and to assess its application in patients. METHODS AND RESULTS The technique involves the administration of 15O-labeled carbon dioxide (C15O2) and rapid dynamic scanning. Arterial and myocardial time activity curves were fitted to a single tissue compartment tracer kinetic model to estimate MBF in each myocardial region. Validation studies consisted of 52 simultaneous measurements of MBF with PET and gamma-labeled microspheres in nine closed-chest dogs over a flow range of 0.5-6.1 ml/g/min. A good correlation between the two methods was obtained (y = 0.36 + 1.0x, r = 0.91). Human studies consisted of 11 normal volunteers and eight patients with chronic stable angina and single-vessel disease, before and after intravenous dipyridamole infusion. In the normal group, MBF was homogeneous throughout the left ventricle both at rest and after administration of dipyridamole (0.88 +/- 0.08 ml/g/min and 3.52 +/- 1.12 ml/g/min, respectively; p less than or equal to 0.001). In patients, resting MBF was similar in the distribution of the normal and stenotic arteries (1.03 +/- 0.23 and 0.93 +/- 0.21 ml/g/min, respectively). After dipyridamole infusion, MBF in normally perfused areas increased to 2.86 +/- 0.83 ml/g/min, whereas in the regions supplied by stenotic arteries it increased to only 1.32 +/- 0.27 ml/g/min (p less than or equal to 0.001). CONCLUSIONS PET with C15O2 inhalation provides an accurate noninvasive quantitative method for measuring regional myocardial blood flow in patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3