Cardiac tamponade in left ventricular dysfunction.

Author:

Hoit B D1,Gabel M1,Fowler N O1

Affiliation:

1. University of Cincinnati Medical Center, Division of Cardiology, Ohio 45267.

Abstract

Echocardiographic and hemodynamic data were measured in closed-chest dogs during graded cardiac tamponade (pericardial pressure 5, 10, and 15 mm Hg) before and after production of diffuse ischemic left ventricular dysfunction. Left ventricular dysfunction was produced by intracoronary injection of nonradioactive microspheres (54 +/- 3.9 mm diameter). Changes in left atrial pressure with cardiac tamponade were influenced by coexisting left ventricular dysfunction. Left atrial pressure increased with tamponade and was equal to pericardial pressure before left ventricular dysfunction was produced. However, after left ventricular dysfunction was produced, left atrial pressure was significantly higher than pericardial pressure before tamponade, but it fell toward pericardial pressure when tamponade was produced. Pulsus paradoxus (greater than 10 mm Hg) was present in all animals with cardiac tamponade before left ventricular dysfunction but in only one animal afterward. During each level of tamponade, the inspiratory fall of aortic systolic pressure was greater before than with left ventricular dysfunction. The slope of the linear regression between pericardial pressure and millimeters of mercury of inspiratory fall in aortic systolic pressure was significantly greater before than with left ventricular dysfunction (0.74 +/- 0.12 versus 0.32 +/- 0.12, p less than 0.05). Left ventricular dysfunction caused a leftward and upward shift of the pericardial pressure-volume relation. As a result, right atrial and ventricular collapse occurred with significantly smaller volumes of pericardial fluid after than before left ventricular dysfunction. We conclude that pulsus paradoxus may be absent in cardiac tamponade with coexisting left ventricular dysfunction and unequal filling pressures. Echocardiographic signs of cardiac tamponade may occur with small effusions in the presence of left ventricular dysfunction.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 55 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3