Detection of myocardial ischemia by 31P magnetic resonance spectroscopy during handgrip exercise.

Author:

Yabe T1,Mitsunami K1,Okada M1,Morikawa S1,Inubushi T1,Kinoshita M1

Affiliation:

1. First Department of Internal Medicine, Shiga University of Medical Science, Otsu, Japan.

Abstract

BACKGROUND The metabolic changes of myocardial ischemia in patients with coronary artery disease assessed by 31P magnetic resonance spectroscopy (MRS) have been reported previously. A significant decrease in the ratio of phosphocreatine (PCr) to ATP during handgrip exercise in a group of patients with severe coronary artery disease has been demonstrated. However, there are no reports at present that directly compare cardiac 31P MRS data with exercise 201Tl myocardial scintigraphy, now established as one of the most important clinical methods to assess myocardial ischemia. The purpose of this study was to investigate whether 31P MRS with handgrip exercise testing is able to detect myocardial ischemia, demonstrated by exercise 201Tl scintigraphy. METHODS AND RESULTS Twenty-seven patients with severe stenosis of the left anterior descending coronary artery (> or = 75%) and 11 normal control subjects composed the present study. Patients were divided into two groups on the basis of exercise 201Tl scintigraphy: a reversible 201Tl defect group (RD[+]) who demonstrated redistribution at the late image and a fixed 201Tl defect group (RD[-]). While lying supine within the magnet, subjects performed handgrip exercise at 30% of maximal force once in every two cardiac cycles. 31P MR spectra were collected before and during handgrip exercise. Data were corrected for the saturation factor. ANOVA revealed significant differences among the three groups with respect to the mean +/- SD PCr/ATP ratio at rest (control, 1.85 +/- 0.28 > RD(+), 1.60 +/- 0.19 > RD(-), 1.24 +/- 0.30; P < .05). The PCr/ATP ratio decreased significantly from 1.60 +/- 0.19 at rest to 0.96 +/- 0.28 during exercise (P < .001) in the RD(+) group (n = 15). However, in the RD(-) group (n = 12), the ratio did not change significantly during handgrip exercise (1.24 +/- 0.30 at rest versus 1.19 +/- 0.28 during exercise). Similarly, the ratio did not change in the control group (n = 11) (1.85 +/- 0.28 at rest versus 1.90 +/- 0.23 during exercise). CONCLUSIONS Contrary to normal subjects or patients with fixed thallium defects, the PCr/ATP ratio was significantly altered by exercise in patients with reversible thallium defects. These results suggest that 31P MRS with handgrip exercise testing is a sensitive method for detecting myocardial ischemia.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 91 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3