Transcatheter occlusion of the persistently patent ductus arteriosus. Forty-month follow-up and prevalence of residual shunting.

Author:

Hosking M C1,Benson L N1,Musewe N1,Dyck J D1,Freedom R M1

Affiliation:

1. Department of Paediatrics, Hospital for Sick Children, Toronto, Ontario, Canada.

Abstract

BACKGROUND Percutaneous closure of the persistently patent ductus arteriosus with the Rashkind prosthesis is an established effective therapeutic modality, although some patients are left with residual shunting. To evaluate this, a retrospective study of the prevalence of persistent shunting over a 40-month period in the first 190 patients was undertaken. METHODS AND RESULTS All patients (male 45, female 145; mean age, 3.9 +/- 3.6 years; range, 5 months to 20 years) had serial clinical and color-flow echocardiographic follow-up at 6-12-month intervals (range, 6-40 months). Four patients required surgical removal of an embolized device, leaving a cohort of 186 patients in whom 196 procedures were performed, resulting in successful placement of 195 devices (43 17-mm [22%] and 152 12-mm [78%]). Complications occurred in seven of 195 procedures (3.6%). Nine of 10 attempted reocclusions (all with 12-mm devices) were successful. The prevalence of residual shunting was 38% at 1 year, 18% at 2 years, and 8% at 40 months. Patients with ductus measuring less than 4 mm had a higher success of initial occlusion. Thirty-four patients were left with residual shunting determined by color-flow Doppler study, but no anatomic or echocardiographic features were found predictive for residual shunting. All remain asymptomatic with 26 (76%) having no detectable murmur, two (6%) a continuous murmur, and six (18%) a systolic murmur. CONCLUSIONS Catheter occlusion will obviate the need for surgery in the majority of patients presenting with persistently patent ductus arteriosus. Reocclusion has been found feasible in those with continuous murmurs (nine of nine) and should be offered early because it is unlikely for spontaneous closure to occur in this group. It appears prudent to follow those with small residual shunting because further spontaneous closure can occur.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference18 articles.

1. Transcatheter closure of patent ductus arteriosus

2. Insertion of patent ductus arteriosus occluder by transvenous approach: A new technique (abstract);Bash SE;Circulation,1985

3. Catheter occlusion of the persistently patent ductus arteriosus

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3