Coronary flow reserve calculated from pressure measurements in humans. Validation with positron emission tomography.

Author:

De Bruyne B1,Baudhuin T1,Melin J A1,Pijls N H1,Sys S U1,Bol A1,Paulus W J1,Heyndrickx G R1,Wijns W1

Affiliation:

1. Cardiovascular Center, Aalst, Belgium.

Abstract

BACKGROUND Experimental studies have shown that fractional flow reserve (defined as the ratio of maximal achievable flow in a stenotic area to normal maximal achievable flow) can be calculated from coronary pressure measurements only. The objectives of this study were to validate fractional flow reserve calculation in humans and to compare this information with that derived from quantitative coronary angiography. METHODS AND RESULTS Twenty-two patients with an isolated, discrete proximal or mid left anterior descending coronary artery stenosis and normal left ventricular function were studied. Relative myocardial flow reserve, defined as the ratio of absolute myocardial perfusion during maximal vasodilation in the stenotic area to the absolute myocardial perfusion during maximal vasodilation (adenosine 140 micrograms.kg-1 x min-1 intravenously during 4 minutes) in the contralateral normally perfused area, was assessed by 15O-labeled water and positron emission tomography (PET). Myocardial and coronary fractional flow reserve were calculated from mean aortic, distal coronary, and right atrial pressures recorded during maximal vasodilation. Distal coronary pressures were measured by an ultrathin, pressure-monitoring guide wire with minimal influence on the trans-stenotic pressure gradient. Minimal obstruction area, percent area stenosis, and calculated stenosis flow reserve were assessed by quantitative coronary angiography. There was no difference in heart rate, mean aortic pressure, or rate-pressure product during maximal vasodilation during PET and during catheterization. Percent area stenosis ranged from 40% to 94% (mean, 77 +/- 13%), myocardial fractional flow reserve from 0.36 to 0.98 (mean, 0.61 +/- 0.17), and relative flow reserve from 0.27 to 1.23 (mean, 0.60 +/- 0.26). A close correlation was found between relative flow reserve obtained by PET and both myocardial fractional flow reserve (r = .87) and coronary fractional flow reserve obtained by pressure recordings (r = .86). The correlations between relative flow reserve obtained by PET and stenosis measurements derived from quantitative coronary angiography were markedly weaker (minimal obstruction area, r = .66; percent area stenosis, r = -.70; and stenosis flow reserve, r = .68). CONCLUSIONS Fractional flow reserve derived from pressure measurements correlates more closely to relative flow reserve derived from PET than angiographic parameters. This validates in humans the use of fractional flow reserve as an index of the physiological consequences of a given coronary artery stenosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 438 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3