Functional significance of collateral blood flow in patients with recent acute myocardial infarction. A study using myocardial contrast echocardiography.

Author:

Sabia P J1,Powers E R1,Jayaweera A R1,Ragosta M1,Kaul S1

Affiliation:

1. Department of Medicine, University of Virginia School of Medicine, Charlottesville.

Abstract

BACKGROUND We hypothesized that myocardial contrast echocardiography (MCE) can be used to both measure collateral blood flow as well as assess the functional significance of collaterals in patients with acute myocardial infarction (AMI). METHODS AND RESULTS MCE was performed in 33 patients with recent AMI (12 +/- 7 days) and an occluded infarct-related artery (IRA), both before and after attempted percutaneous transluminal coronary angioplasty (PTCA). The size of the occluded bed was defined in patients with successful PTCA by injecting contrast directly into the opened IRA and expressed as a percent of the myocardium in the short-axis view. The percent of the perfusion bed supplied by collaterals before PTCA was determined. Transit rates of the microbubbles within the collateralized regions were also measured and were expressed as a percent of the transit rates in the normal adjacent beds. Regional function within the occluded bed was assessed using echocardiography and was graded as 1 (normal) to 5 (dyskinetic). Collaterals were graded on coronary angiography as 0 (none) to 3 (abundant). The perfusion bed size was larger for the left anterior descending (LAD) than for the right (RCA) and left circumflex (LCx) coronary arteries (37 +/- 6% versus 27 +/- 12% of the myocardium, p = 0.02). The percent of the occluded bed supplied by collateral flow was greater for RCA and LCx compared with the LAD (87 +/- 30% versus 72 +/- 22%, p less than 0.01). There was poor correlation between MCE-defined percent of occluded bed supplied by collaterals and angiographic collateral grade (r = 0.13). Regions supplied by collaterals were less likely to show confluent hypoperfused zones after reperfusion compared with those not supplied by collaterals. Similarly, the percent of myocardium not perfused by either anterograde or collateral flow correlated well (r = 0.67, p less than 0.01) with peak creatine kinase levels and was more likely to be associated with Q waves. Finally, although there was poor correlation between angiographic collaterals and regional function (r = 0.20), there was a significant negative correlation between MCE-defined spatial extent of collateral flow and regional function (r = -0.57, p less than 0.01). CONCLUSION MCE can be used to measure collateral flow in patients with recent AMI and to assess the functional significance of collaterals in these patients. This technique may be ideally suited for the assessment of collateral perfusion in patients undergoing cardiac catheterization.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3