Relative risk analysis of angiographic predictors of restenosis within the coronary Wallstent.

Author:

Strauss B H1,Serruys P W1,de Scheerder I K1,Tijssen J G1,Bertrand M E1,Puel J1,Meier B1,Kaufmann U1,Stauffer J C1,Rickards A F1

Affiliation:

1. Catheterization Laboratory, Thoraxcenter, Rotterdam, The Netherlands.

Abstract

BACKGROUND Late angiographic narrowing has been observed following coronary implantation of the Wallstent. To identify the angiographic variables that predict restenosis within the stented segment, a retrospective study of data from the European Wallstent core laboratory was performed. METHODS AND RESULTS Follow-up angiograms (excluding patients with in-hospital occlusions) were analyzed for 214 lesions in 176 patients (78% restudy rate). The incidence of restenosis within the stented segment was 35% by lesion and 35% by patient for criterion 1 (greater than or equal to 0.72 mm loss in minimal luminal diameter) and 24% by lesion and 24% by patient for criterion 2 (diameter stenosis greater than or equal to 50% at follow-up). The association between 16 variables and restenosis was determined by a relative risk ratio assessment. Variables with significant risk ratios for restenosis with criterion 1 were use of multiple stents/lesion (relative risk, 1.56; 95% confidence interval [CI], 1.08-2.25) and oversized (unconstrained stent diameter exceeding reference diameter greater than 0.7 mm) stents (relative risk, 1.64; 95% CI, 1.10-2.45), and for criterion 2, oversizing by more than 0.70 mm (relative risk, 1.93; 95% CI, 1.13-3.31), bypass grafts (relative risk, 1.62; 95% CI, 0.98-2.66), use of multiple stents/lesion (relative risk, 1.61; 95% CI, 0.97-2.67) and residual diameter stenosis more than 20% post stenting (relative risk, 1.51; 95% CI, 0.91-2.50). CONCLUSIONS It is concluded that several angiographic variables are significantly associated with late angiographic narrowing after stenting in the coronary arteries. We suggest that stent operators avoid excessive oversizing in the selection of stent diameter and the use of multiple stents per lesion to lessen the risk of late restenosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 123 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. State-of-art review: intravascular imaging in percutaneous coronary interventions;Cardiology Plus;2023-10

2. JCS/JSCVS 2018 Guideline on Revascularization of Stable Coronary Artery Disease;Circulation Journal;2022-02-25

3. Long‐term clinical outcomes after drug eluting stent implantation with and without stent overlap;Catheterization and Cardiovascular Interventions;2021-09-06

4. Disease Interactome;Epidemiological Research Applications for Public Health Measurement and Intervention;2021

5. Patient-specific modelling of stent overlap: Lumen gain, tissue damage and in-stent restenosis;Journal of the Mechanical Behavior of Biomedical Materials;2020-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3