Relation of clinical presentation, stenosis morphology, and operator technique to the procedural results of rotational atherectomy and rotational atherectomy-facilitated angioplasty.

Author:

Ellis S G1,Popma J J1,Buchbinder M1,Franco I1,Leon M B1,Kent K M1,Pichard A D1,Satler L F1,Topol E J1,Whitlow P L1

Affiliation:

1. Department of Cardiology, Cleveland Clinic Foundation, Ohio 44195.

Abstract

BACKGROUND Rotational atherectomy using the Rotablator has recently become available to treat coronary stenoses. This study was performed to determine the relation of patient characteristics, stenosis morphology, and operator technique to procedural outcome to gain insight into which patients might be best treated with this device. METHODS AND RESULTS Four hundred stenoses from 316 patients randomly selected from the initial Rotablator experience at three major referral institutions were analyzed. Angiographic data were assessed at a central angiographic laboratory using standardized morphological criteria and caliper measurement. Patients were somewhat more elderly than most percutaneous transluminal coronary angioplasty (PTCA)-treated groups (mean age, 64 +/- 11 years), 74% were men, and the lesions treated were often complex (modified American College of Cardiology/American Heart Association lesion type A, 24%; B1, 40%; B2, 30%; and C, 6%). Elective adjunctive PTCA was used for 82% of stenoses treated. Procedural success was achieved in 89.8% of stenoses (93.5% if results with creatine kinase two to three times normal are not counted as failures), and major ischemic complications (death, 0.3%; non-Q-wave myocardial infarction, 5.7%; Q-wave myocardial infarction, 2.2%; or emergency bypass surgery, 0.9%) occurred in 8.9% of patients. Complications were due to epicardial coronary obstruction in 3.8% of patients and to delayed coronary runoff ("slow reflow") in 5.1% of patients. Procedural failure was correlated independently with outflow obstruction (success rate, 64%; odds ratio for failure, 5.4; multivariate P = .002), lesion irregularity (76%; odds ratio, 3.3; P = .003), stenosis bend > or = 60 degrees (73%; odds ratio, 3.7; P = .03), and female sex (84%; odds ratio, 2.4; P = .03). Ischemic complications were correlated independently with lesion length (> or = 50% narrowing) > or = 4 mm (complication rate, 12%; odds ratio, 3.6; multivariate P = .005), right coronary artery stenosis (13%; odds ratio, 2.4; P = .02), stenosis bend > or = 60 degrees (27%; odds ratio, 6.1; P = .03), and female sex (13%; odds ratio, 3.0; P = .04). Slow reflow was correlated with total burring duration (odds ratio, 1.005/s; multivariate P = .001), right coronary artery stenosis (incidence, 17%; odds ratio, 4.5; P = .009), and to a lesser extent with recent myocardial infarction in the treated territory (44%; odds ratio, 4.3; P = .08). CONCLUSIONS The procedural outcome of rotational atherectomy is highly correlated with stenosis morphology and location and sex of the patient. After stratification for these parameters, overall outcome with the Rotablator appears to be similar to that with balloon angioplasty and other competing techniques. Short-term outcome with specific subsets of patients may be superior with the Rotablator (calcified stenoses), but this technique might best be avoided in some patients (those with irregular or possibly thrombus-containing stenoses, highly angulated stenoses, and possible right coronary artery stenoses or those associated with impaired distal runoff caused by a recent myocardial infarction or manifest by a fixed thallium defect).

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3