The ability of several short-term measures of RR variability to predict mortality after myocardial infarction.

Author:

Bigger J T1,Fleiss J L1,Rolnitzky L M1,Steinman R C1

Affiliation:

1. Department of Medicine, School of Public Health, Columbia University, New York, NY 10032.

Abstract

BACKGROUND We studied 715 patients 2 weeks after myocardial infarction to test the hypothesis that short-term power spectral measures of RR variability (calculated from 2 to 15 minutes of normal RR interval data) will predict all-cause mortality or arrhythmic death. METHODS AND RESULTS We performed power spectral analyses on the entire 24-hour RR interval time series. To compare with the 24-hour analyses, we selected short segments of ECG recordings from two time periods for analysis: 8 AM to 4 PM and midnight to 5 AM. The former corresponds to the time interval during which short-term measures of RR variability would most likely be obtained. The latter, during sleep, represent a period of increased vagal tone, which may simulate the conditions that exist when patients have a signal-averaged ECG recorded, ie, lying quietly in the laboratory. Four frequency domain measures were calculated from spectral analysis of heart period data over a 24-hour interval. We computed the 24-hour power spectral density and calculated the power within three frequency bands: (1) 0.0033 to < 0.04 Hz, very low frequency power, (2) 0.04 to < 0.15 Hz, low frequency power, and (3) 0.15 to 0.40 Hz, high frequency power. In addition, we calculated the ratio of low to high frequency power. These measures were calculated for 15-, 10-, 5-, and 2-minute segments during the day and at night. Mean power spectral values from short periods during the day and night were similar to 24-hour values, and the correlations between short segment values and 24-hour values were strong (many correlations were > or = 0.75). Using the optimal cutpoints determined previously for the 24-hour power spectral values, we compared the survival experience of patients with low values for RR variability in short segments of ECG recordings to those with high values. We found that power spectral measures of RR variability were excellent predictors of all-cause, cardiac, and arrhythmic mortality and sudden death. Patients with low values were 2 to 4 times as likely to die over an average follow-up of 31 months as were patients with high values. The power spectral measures of RR variability did not predict arrhythmic or sudden deaths substantially better than all-cause mortality. CONCLUSIONS Power spectral measures of RR variability calculated from short (2 to 15 minutes) ECG recordings are remarkably similar to those calculated over 24 hours. The power spectral measures of RR variability are excellent predictors of all-cause mortality and sudden cardiac death.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3