Noninvasive measurement of rate of left ventricular relaxation by Doppler echocardiography. Validation with simultaneous cardiac catheterization.

Author:

Nishimura R A1,Schwartz R S1,Tajik A J1,Holmes D R1

Affiliation:

1. Division of Cardiovascular Diseases and Internal Medicine, Mayo Clinic, Rochester, MN 55905.

Abstract

BACKGROUND The instantaneous pressure gradient between the left ventricle and left atrium during systole can be calculated from the mitral regurgitation Doppler velocity curve. The purpose of our study was to determine the accuracy of measuring the time constant of relaxation (TAU) derived from the Doppler mitral regurgitation signal by comparing it with simultaneous high-fidelity left ventricular pressure measurements in humans. METHODS AND RESULTS Twenty-five patients had continuous-wave Doppler mitral regurgitation recordings performed with simultaneous high-fidelity left ventricular pressure measurements. Fifteen of these patients had measurements of six to eight beats at various RR intervals. Doppler velocity curves were converted to left ventricular pressure curves by different methods through application of the modified Bernoulli equation at 3-msec intervals. The correlation between catheter-derived and Doppler-derived TAU was best when a zero asymptote and knowledge of the left ventricular end-diastolic pressure were used. A less optimal but acceptable method used the addition of 20 mm Hg to the Doppler-derived ventriculoatrial gradient. Use of a nonzero asymptote for calculation of TAU yielded poor correlation between catheter and Doppler measurements. The correlation of percentage change in Doppler-derived TAU plotted against percentage change in catheter-derived TAU was poor. CONCLUSIONS The descending limb of the Doppler-derived mitral regurgitation velocity signal can be used as a semiquantitative estimate of the rate of ventricular relaxation. This method requires knowledge of left atrial pressure and may not be sufficiently accurate for detecting small changes in the rate of relaxation on a beat-to-beat basis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3