Determination of the most appropriate velocity threshold for applying hemispheric flow convergence equations to calculate flow rate: selected according to the transorifice pressure gradient. Digital computer analysis of the Doppler color flow convergence region.

Author:

Deng Y B1,Shiota T1,Shandas R1,Zhang J1,Sahn D J1

Affiliation:

1. Clinical Care Center for Congenital Heart Disease, Oregon Health Sciences University, Portland 97201.

Abstract

BACKGROUND While flow convergence methods have been promising for calculating volume flows from color Doppler images, it appears that the velocity threshold used and the transorifice pressure gradient dramatically influence the accuracy of application of the simple hemispheric flow convergence equation for calculation of flow rate. The present in vitro study was performed to determine whether the value of velocity threshold at which the shape of proximal isovelocity surface best fits given shape assumptions with different orifice sizes and flow rates is predictable as a function independent of orifice size from clinically measurable peak velocity or transorifice pressure gradient information. METHODS AND RESULTS In an in vitro model built to facilitate ultrasound imaging, steady flow was driven through circular discrete orifices with diameters of 3.8, 5.5, and 10 mm. Flow rates ranged from 2.88 to 8.28 L/min with corresponding driving pressure gradients from 14 to 263 mm Hg. At each flow rate, Doppler color-encoded M-mode images through the center of the flow convergence region were obtained and transferred into the microcomputer (Macintosh IIci) in their original digital format. Then, the continuous wave Doppler traces of maximal velocity through the orifice were derived for the calculation of driving pressure gradient. Direct numerical spatial velocity measurements were obtained from the digital color encoded M-mode velocities with computer software. For each flow rate, we could calculate flow volume from any number of velocity distance combinations with a number of assumptions and use the results to assess expected flow convergence shape based on a priori knowledge of the progression from oblate hemispheroid to hemisphere to prolate hemispheroid changes observed previously. Our results showed that for a given ratio of calculated flow rate to actual flow rate (0.7 and 1), the velocity threshold that could be used for the calculation of flow rate with a hemispheric flow convergence equation correlated well with the pressure gradient for a given orifice size, and the differences in velocity threshold that could be used this way among different orifice sizes once they were adjusted for the covariate pressure gradients were not statistically significant (P = .79 for ratio = 0.7, and P = .81 for ratio = 1). CONCLUSIONS Our present study provides an orifice size-independent quantitative method that can be used to select the most suitable velocity threshold for applying a simple hemispheric flow convergence equation based on clinically predictable pressure gradients ranging from 40 to 200 mm Hg, and it offers a correction factor that can be applied to the hemispheric flow convergence equation when the pressure gradient is less than 40 mm Hg.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3