Temperature monitoring during radiofrequency catheter ablation of accessory pathways.

Author:

Langberg J J1,Calkins H1,el-Atassi R1,Borganelli M1,Leon A1,Kalbfleisch S J1,Morady F1

Affiliation:

1. Department of Internal Medicine, University of Michigan Medical Center, Ann Arbor 48109-0022.

Abstract

BACKGROUND Animal studies have suggested that the temperature of the electrode-tissue interface during radiofrequency catheter ablation accurately predicts lesion size. The purpose of the current study was to evaluate the utility of continuous temperature monitoring during radiofrequency catheter ablation in patients with Wolff-Parkinson-White syndrome. METHODS AND RESULTS Twenty patients with manifest preexcitation were included in the study. The ablation catheter was positioned on the ventricular side of the mitral annulus for left-sided accessory pathways and on the atrial side of the tricuspid annulus for right-sided and septal accessory pathways. A thermistor imbedded in the distal electrode of the ablation catheter allowed continuous temperature monitoring during each energy application. To define the relation between power and temperature, radiofrequency current was applied several times at each site using outputs of 20, 30, 40, and 50 W. The accessory pathways were successfully ablated in each of the 20 patients. Because of marked variability in the efficiency of heating between sites, power output did not predict temperature. However, at any given site, there was a positive dose-response relation between power and temperature. Radiofrequency energy applications on the atrial side of the tricuspid annulus produced lower temperatures than did applications on the ventricular side of the mitral annulus (49 +/- 7 versus 60 +/- 16 degrees C, p = 0.0001). Transient block in the accessory pathways occurred at a mean of 50 +/- 8 degrees C, whereas permanent block was seen at a mean of 62 +/- 15 degrees C (p = 0.0001). Less than half of the applications at outputs < or = 40 W produced temperatures adequate to interrupt accessory pathway conduction. An abrupt rise in impedance caused by coagulum formation occurred only at temperatures between 95 and 100 degrees C. CONCLUSIONS Temperature monitoring may facilitate radiofrequency catheter ablation of accessory pathways. By adjusting power output to ensure that adequate but not excessive temperatures have been achieved, a rise in impedance can be avoided and the total number of energy applications and procedure duration may be reduced.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 155 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3