Platelet factor 4 efficiently reverses heparin anticoagulation in the rat without adverse effects of heparin-protamine complexes.

Author:

Cook J J1,Niewiarowski S1,Yan Z1,Schaffer L1,Lu W1,Stewart G J1,Mosser D M1,Myers J A1,Maione T E1

Affiliation:

1. Department of Physiology, Temple University School of Medicine, Philadelphia, PA 19140.

Abstract

BACKGROUND It has been observed that the reversal of heparin anticoagulation in humans by protamine sulfate (PS) results in various adverse reactions including leukopenia, thrombocytopenia, activation of complement, increased vascular permeability, systemic hypotension, pulmonary vasoconstriction, and pulmonary edema. The purpose of this study was to compare the efficacy and effects of native platelet factor 4 (PF4) and recombinant platelet factor 4 (rPF4) with those of PS in heparin neutralization in vivo, using a rat model. METHODS AND RESULTS Sprague-Dawley rats were anesthetized with sodium pentobarbital, and the right femoral vein and carotid artery were cannulated. For determination of activated partial thromboplastin time, platelet count, white blood cell count, and complement titer, arterial blood samples were taken before and immediately after heparin (10 units/100 g) infusion and at several time points after the infusion of the neutralizing agent (PS, 0.1 mg/100 g; PF4, 0.5 mg/100 g). In separate groups of animals, mean arterial blood pressure was monitored throughout identical protocols and the lungs were prepared for histological examination. The anticoagulant activity of heparin was effectively reversed by all of the neutralizing agents (PS, PF4, and rPF4). Platelet count (48% of initial), white blood cell count (52% of initial), complement titer (60% of initial), and mean arterial pressure (20% decrease) decreased significantly in heparinized animals receiving PS but not in those receiving PF4 or rPF4. Lung interstitium appeared normal when heparin was followed by PF4; however, interstitial edema and hemorrhage were observed with heparin-PS. CONCLUSIONS These results suggest that PF4 efficiently reverses heparin anticoagulation in the rat without the adverse effects of heparin-protamine complexes. Therefore, rPF4 may be an appropriate substitute for PS in patients undergoing cardiovascular surgery and other procedures that require heparin anticoagulation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 35 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3