Dipyridamole thallium-201 scintigraphy as a preoperative screening test. A reexamination of its predictive potential. Study of Perioperative Ischemia Research Group.

Author:

Mangano D T1,London M J1,Tubau J F1,Browner W S1,Hollenberg M1,Krupski W1,Layug E L1,Massie B1

Affiliation:

1. Department of Anesthesia, University of California, San Francisco.

Abstract

BACKGROUND We examined the value of dipyridamole thallium-201 (201Tl) scintigraphy as a preoperative screening test for perioperative myocardial ischemia and infarction. METHODS AND RESULTS We prospectively studied 60 patients undergoing elective vascular surgery. We performed 201Tl scintigraphy preoperatively and blinded all treating physicians to the results. Historical, clinical, laboratory, and physiological data were gathered throughout hospitalization. Myocardial ischemia was assessed during the intraoperative period using continuous 12-lead electrocardiography (ECG) and transesophageal echocardiography (TEE) and during the postoperative period using continuous two-lead ambulatory ECG. Adverse cardiac outcomes (cardiac death, myocardial infarction, unstable angina, severe ischemia, or congestive heart failure) were assessed daily throughout hospitalization. Twenty-two patients (37%) had defects that improved or reversed on delayed scintigrams (redistribution defects), 18 (30%) had persistent defects, and 20 (33%) had no defects on 201Tl scintigraphy. There was no association between redistribution defects and adverse cardiac outcomes: 54% (seven of 13) of adverse outcomes occurred in patients without redistribution defects, and the risk of an adverse outcome was not significantly increased in patients with redistribution defects (relative risk 1.5, 95% confidence interval 0.6-3.9, p = 0.43). Consistent with these findings, there was also no association between redistribution defects and perioperative ischemia: 54% (19 of all 35) of perioperative ECG and TEE ischemic episodes and 58% (14 of 24) of severe ischemic episodes occurred in patients without redistribution defects. The sensitivity of 201Tl scintigraphy for perioperative ischemia and adverse outcomes ranged from 40% to 54%, specificity from 65% to 71%, positive predictive value from 27% to 47% and negative predictive value from 61% to 82%. CONCLUSIONS These results differ from those of previous studies and suggest that the routine use of 201Tl scintigraphy for preoperative screening of patients undergoing vascular surgery may not be warranted.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference39 articles.

1. National Center for Health Statistics: Health United States 1988. US Dept of Health and Human Services publication No. (PHS) 89-1232. Washington DC US Government Printing Office 1989 pp 10-17 66 67 100 101

2. National Center for Health Statistics: Health United States 1988. US Dept of Health and Human Services publication No. (PHS) 89-1232. Washington DC US Government Printing Office 1989 pp 111-122 175

3. Perioperative Cardiac Morbidity

4. Myocardial Infarction After General Anesthesia

5. Multifactorial Index of Cardiac Risk in Noncardiac Surgical Procedures

Cited by 235 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3