Selection of the optimal nonexercise stress for the evaluation of ischemic regional myocardial dysfunction and malperfusion. Comparison of dobutamine and adenosine using echocardiography and 99mTc-MIBI single photon emission computed tomography.

Author:

Marwick T1,Willemart B1,D'Hondt A M1,Baudhuin T1,Wijns W1,Detry J M1,Melin J1

Affiliation:

1. Division of Cardiology, Cliniques Universitaires St. Luc, University of Louvain, Brussels, Belgium.

Abstract

BACKGROUND The mechanisms of action of exercise-simulating and vasodilator stressors support their combination with imaging techniques that evaluate left ventricular function and perfusion, respectively. However, reported accuracies of either pharmacological stress together with two-dimensional echocardiography (2DE) or single photon emission computed tomography (SPECT) of myocardial perfusion are similar. The purpose of this study was to establish the optimal stress for each imaging technique by comparing the results of digitized 2DE and 99mTc-methoxyisobutyl isonitrile (MIBI) SPECT using both dobutamine and adenosine stresses in the same patients and conditions. METHODS AND RESULTS Ninety-seven consecutive patients without evidence of previous infarction undergoing coronary angiography for clinical indications were studied prospectively. Dobutamine was infused during clinical, ECG, and echocardiographic monitoring in dose increments from 5 to 40 micrograms.kg-1.min-1. Adenosine was infused under the same conditions in doses of 0.10, 0.14, and 0.18 mg.kg-1.min-1. For each protocol, the end points were achievement of peak dose, development of severe ischemia, or intolerable side effects. At peak stress, 20 mCi of MIBI was injected, and SPECT imaging was performed 2 hours later; abnormal poststress images were compared with resting SPECT: Digitized 2DE images were compared qualitatively before, during, and after stress in a cine-loop display. Significant coronary disease (n = 59 patients) was defined by the quantification of > 50% stenosis in a major epicardial vessel. The sensitivity of adenosine 2DE was 58%, less than those of adenosine MIBI (86%, p = 0.001), dobutamine 2DE (85%, p = 0.001), and dobutamine MIBI (80%, p = 0.01). Their respective specificities were 87%, 71%, 82%, and 74% (p = NS). The accuracy of adenosine 2DE was 69%, compared with 80% for adenosine MIBI (p < 0.001), 84% for dobutamine 2DE (p = 0.001), and 77% for dobutamine MIBI (p = 0.005); the latter three did not differ significantly in either sensitivity or accuracy. CONCLUSIONS This prospective, direct comparison of alternative pharmacological stresses in patients without myocardial infarction shows vasodilator stress scintigraphy and dobutamine stress echocardiography and scintigraphy to share equivalent levels of sensitivity. All three are significantly more sensitive than adenosine stress echocardiography. Dobutamine stress may be used for wall motion or perfusion imaging, but adenosine stress is best combined with perfusion scintigraphy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 306 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3