Radiation exposure during radiofrequency catheter ablation of accessory atrioventricular connections.

Author:

Calkins H1,Niklason L1,Sousa J1,el-Atassi R1,Langberg J1,Morady F1

Affiliation:

1. University of Michigan Medical Center, Division of Cardiology, Ann Arbor 48109-0022.

Abstract

BACKGROUND Catheter ablation of accessory atrioventricular (AV) connections has been demonstrated to be effective in more than 85% of patients. One of the risks of this procedure is radiation exposure during the fluoroscopic imaging necessary to guide catheter manipulation. The objective of the present study was to measure the radiation received by patients and physicians during radiofrequency catheter ablation and to estimate the resultant somatic and genetic risks. METHODS AND RESULTS Radiation exposure to patients and physicians was measured during attempts at radiofrequency catheter ablation of accessory AV connections in 31 consecutive patients. Radiation exposure was measured using thermoluminescent sensors placed on the patient and on the physician. Somatic and genetic risks were estimated based on the radiation levels recorded using these sensors. The durations of fluoroscopy and of the catheter ablation procedure were recorded for each patient. Catheter ablation was successful in 28 of 31 patients (90%). Mean +/- SD duration of fluoroscopy was 44 +/- 40 minutes. The largest patient radiation dose was measured over the ninth vertebral body posteriorly (median, 7.26 rem [roentgen equivalents man]; range, 0.31-135.7 rem). Median radiation dose to the thyroid was 0.46 rem (range, 0.06-7.26 rem), and median radiation dose to the posterior iliac crest was 2.43 rem (range, 0.01-8.3 rem). The greatest radiation dose to the operator was recorded at the left hand (99 mrem). Mean radiation dose to the operator's eyes was 28 mrem. CONCLUSIONS Radiofrequency catheter ablation of accessory AV connections may result in significant radiation exposure to the patient and to the physician. Each hour of fluoroscopic imaging is associated with a lifetime risk of developing a fatal malignancy of 0.1% and a risk of a genetic defect of 20 per 1 million births. Although these risks must be recognized, they are relatively small compared with the risks associated with alternate approaches to management, including no therapy, antiarrhythmic drug therapy, and surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3