Comparison of 99mTc-teboroxime with thallium for myocardial imaging in the presence of a coronary artery stenosis.

Author:

Gray W A1,Gewirtz H1

Affiliation:

1. Department of Medicine, Rhode Island Hospital, Providence 02903.

Abstract

BACKGROUND This study tested the hypotheses in the setting of a coronary artery stenosis that 1) planar 99mTc-teboroxime myocardial scans are capable of providing a good estimate of relative coronary flow reserve, and 2) delayed washout of the tracer from the myocardium is a marker of reduced myocardial blood flow and, in certain cases, myocardial ischemia. METHODS AND RESULTS Experiments were conducted in eight closed-chest domestic swine prepared with an artificial stenosis that reduced diameter of the left anterior descending coronary artery by 80%. Measurements of hemodynamics, regional myocardial blood flow, oxygen, and lactate metabolism were made 1) at baseline, 2) after 5 minutes of intravenous infusion of adenosine and neosynephrine ("stress"), and 3) at recovery 2 hours after discontinuing the adenosine/neosynephrine infusion. Simultaneous intravenous injection of teboroxime (approximately 9 mCi) and thallium (approximately 3.5 mCi) was made at peak stress, and serial planar teboroxime imaging began 1-2 minutes later. Scans were made in dynamic mode for 30 seconds each for 7 minutes after which a stress thallium scan (7 minutes acquisition) was obtained. A redistribution thallium scan was made 2 hours later after which a repeat teboroxime injection followed by serial imaging for 7 minutes was performed. The animal was then killed, and the heart removed for determination of microsphere activity. Under baseline conditions, transmural myocardial blood flow (ml/min/g) distal to the stenosis (1.06 +/- 0.17) was reduced (p less than 0.01) compared with the normally perfused circumflex zone (1.50 +/- 0.31). In response to intravenous infusion of adenosine/neosynephrine, flow increased (p less than 0.01) compared with baseline in both distal (2.00 +/- 0.84) and circumflex (4.67 +/- 1.55) zones. However, the distal : circumflex flow declined (0.45 +/- 0.17) compared with baseline (0.73 +/- 0.17; p less than 0.01). Two hours later flow had returned to baseline levels in both zones, and lactate production during stress (-41.7 +/- 37.5 mumol/min/100 g) had reverted to consumption (13.6 +/- 7.7; p less than 0.05). Analysis of stress teboroxime scans demonstrated 1) an increase (p less than 0.01) in the ischemic : normal zone (IZ:NZ) count between 30-second (0.50 +/- 0.14) and 7-minute scans (0.61 +/- 0.11); 2) a good correlation between the 30-second scan IZ:NZ count and the stress distal : circumflex flow (0.45 +/- 0.17; r = 0.74; p less than 0.05; slope = 0.90; intercept = 0); and 3) a close correlation between the IZ:NZ count of the 7-minute scan (0.61 +/- 0.11) and the recovery distal : circumflex flow (0.69 +/- 0.21; r = 0.89; p less than 0.01). The IZ:NZ count also increased (p less than 0.01) between 30-second (0.65 +/- 0.15) and 7-minute (0.72 +/- 0.14) scans following rest injection of teboroxime. As anticipated, serial thallium scans demonstrated evidence of redistribution between stress (IZ:NZ count = 0.62 +/- 0.08) and recovery (IZ:NZ count = 0.75 +/- 0.06; p less than 0.01) time points. The stress thallium scan IZ:NZ, however, was greater than that of the 30-second teboroxime scan as well as that of the stress distal : circumflex flow. CONCLUSIONS Accordingly, the data indicate that 1) myocardial imaging with 99mTc-teboroxime is valuable in the noninvasive assessment of relative coronary flow reserve and that 2) delayed washout of the tracer from the myocardium reflects reduced myocardial blood flow and, under conditions comparable to those of the present study, may be a marker of myocardial ischemia.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference36 articles.

1. Comparative myocardial extraction of two technetium labeled BATO derivatives (SQ30217, SQ30214) and thallium;Leppo JA;J Nucl Med,1990

2. Clearance kinetics of technetium-99m-SQ30217: A marker of regional myocardial blood flow;Stewart RE;J Nucl Med,1990

3. Total and Regional Coronary Blood Flow Measured by Radioactive Microspheres in Conscious and Anesthetized Dogs

Cited by 35 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3