Noninvasive determination of coronary artery bypass graft patency by cine magnetic resonance imaging.

Author:

Aurigemma G P1,Reichek N1,Axel L1,Schiebler M1,Harris C1,Kressel H Y1

Affiliation:

1. Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia 19104.

Abstract

Cine magnetic resonance imaging (MRI) is a gradient-recalled, retrospectively gated, fast-scan technique that depicts laminar flowing blood as bright signal and has been proposed as a useful method for determination of coronary artery bypass graft (CABG) patency. Therefore, we performed a blinded prospective study to assess the value of cine MRI determination of CABG patency in 20 patients with 45 CABG proximal anastomoses who were undergoing repeat angiography. Ten normal subjects served as controls to define normal intrathoracic vascular patterns. There were 21 left anterior descending (LAD) grafts, of which four were left internal mammary (LIMA), 12 left circumflex (Cx), and 12 right coronary (RCA) grafts. After localizing spin-echo coronal images were obtained, multiple axial multislice interleaved cine MRI acquisitions, each consisting of two to four 5-10-mm-thick slices at eight to 24 frames per cardiac cycle, were obtained from the superior main pulmonary artery to the inferior left ventricle. Each acquisition took 5-8 minutes with a subsequent 5-10 minutes of computer image reconstruction. Total study time per patient was 50-75 minutes. Known to cine MRI interpreters were the original surgical CABG insertions but not the angiographic findings. A graft was called patent if a bright graft flow signal, not corresponding to a normal vessel, was identified on multiple frames at multiple levels abutting the great vessels or epicardial surface of the heart. Angiographically, there were 33 patent grafts, of which 29 were identified as patent by cine MRI (sensitivity, 88%).(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference25 articles.

1. Cine MR imaging: potential for the evaluation of cardiovascular function

2. Correlation of Cine MR Imaging with Two-Dimensional Pulsed Doppler Echocardiography in Valvular Insufficiency

3. Evaluation of mitral regurgitation by cardiac cine magnetic resonance imaging;Aurigemma G;Circulation,1987

4. Aurigemma G Reichek N Schiebler M Axel L Harris C Bogin K Muhammad A Douglas P Berko B Kressel H: Evaluation of aortic regurgitation by cine magnetic reso- nance imaging. JAm Coll Cardiol 1988;11:155A

5. Comparison of cine magnetic resonance imaging with Doppler-echocardiography for the evaluation of aortic regurgitation;Pflugfelder PW;Circulation,1987

Cited by 131 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Cardiovascular Magnetic Resonance Angiography;Cardiac CT, PET & MR;2019-07-05

2. Coronary Artery Bypass Graft Imaging and Assessment of Flow;Cardiovascular Magnetic Resonance;2019

3. Coronary Artery Imaging;Cardiovascular Magnetic Resonance;2019

4. Noncontrast Coronary Artery Imaging;Magnetic Resonance Angiography;2011-11-26

5. Noninvasive Coronary Artery Imaging: Current Clinical Applications;Heart, Lung and Circulation;2011-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3