Characterization of spatial patterns of flow within the reperfused myocardium by myocardial contrast echocardiography. Implications in determining extent of myocardial salvage.

Author:

Villanueva F S1,Glasheen W P1,Sklenar J1,Kaul S1

Affiliation:

1. Cardiovascular Division, University of Virginia School of Medicine, Charlottesville 22908.

Abstract

BACKGROUND Since myocardial blood flow changes dynamically after reperfusion and since both hyperemia and impairment in microvascular function exist within the acutely reperfused bed, we sought to investigate the role of myocardial contrast echocardiography (MCE) in (1) defining the temporal variability in perfusion patterns after reflow and relating these to microsphere-derived blood flow; (2) differentiating viable from infarcted tissue during different periods of reflow; and (3) defining spatial perfusion patterns within the infarct bed in response to exogenously induced maximal vasodilation and relating these to infarct size and extent of myocardial salvage. METHODS AND RESULTS Twenty-one dogs with 3 hours of left anterior descending coronary artery occlusion and 2 to 3 hours of reflow were studied. MCE was performed at 15 and 45 minutes and 2 and 3 hours after reflow. It was also performed at either 2 or 3 hours after reflow in the presence of 0.56 mg/kg of dipyridamole. Radiolabeled microsphere-derived blood flow was measured at 15 minutes and 2 and 3 hours after reflow and during dipyridamole effect. Infarct size was measured at the end of the experiment by use of triphenyl tetrazolium chloride. MCE data were processed with color-coding schemes that highlighted differences in myocardial videointensities in proportion to the concentration of microbubbles within the microvasculature. There was significant variability in MCE-defined perfusion patterns after reflow, with contrast defects noted mainly within the endocardium. There were fair and significant (P < .05) correlation (r = -.73 to r = -.55) between MCE defect size and normalized endocardial blood flow. Except at 15 minutes after reflow, there was poor correlation (r = .31 to r = .51) between MCE defect and infarct sizes. Even at 15 minutes after reflow, MCE defect size underestimated infarct size by 50%. In comparison, in the presence of dipyridamole, MCE defect size correlated strongly (r = .87, P < .001) with infarct size and reasonably well with normalized transmural blood flow (r = -.62, P = .04). Moreover, the topography of the MCE perfusion defect reflected the topography of the infarct. CONCLUSIONS MCE revealed striking temporal heterogeneity in the spatial distribution of myocardial perfusion during postischemia reflow and either significantly underestimated or did not correlate with infarct size during reperfusion. Because of abnormalities in coronary vascular reserve specific to infarcted tissue, MCE in conjunction with intravenous dipyridamole depicted, in vivo, the actual topography of the infarct with remarkable accuracy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 153 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3