Increased aortic impedance precedes peripheral vasoconstriction at the early stage of ventricular failure in the paced canine model.

Author:

Eaton G M1,Cody R J1,Binkley P F1

Affiliation:

1. Ohio State University, Department of Medicine, Columbus 43210.

Abstract

BACKGROUND Aortic input impedance is altered in patients with congestive heart failure. However, little is known about whether this vascular response is an early change or a late manifestation of left ventricular dysfunction. METHODS AND RESULTS This investigation used a paced canine model of congestive heart failure to demonstrate that abnormal aortic input impedance does evolve in the setting of ventricular systolic dysfunction and to prospectively define the time course of change in aortic input impedance and conduit vessel compliance. Studies were performed in closed-chest conditioned beagles aged 1 to 2 years that underwent hemodynamic evaluation at baseline and after induction of left ventricular dysfunction by rapid ventricular pacing. Within 48 hours of the onset of rapid ventricular pacing, we observed mild left ventricular systolic dysfunction with an echocardiographically derived left ventricular ejection fraction of 37% (p < .001 compared with baseline) measured during interruption of rapid ventricular pacing. Concomitant with this reduction in left ventricular systolic function, the aortic input impedance spectrum was shifted above baseline in all dogs studied. Characteristic impedance of the aorta significantly increased from 121 +/- 65 dynes.s/cm5 to 186 +/- 114 dynes.s/cm5 (P < .02), and a significant increase in the first modulus of impedance from 137 +/- 43 dynes.s/cm5 to 228 +/- 139 dynes.s/cm5 was observed (P < .05). Although characteristic aortic impedance increased by 50%, there was at this point no change in peripheral vascular resistance. Therefore, these abnormalities in aortic input impedance are representative of an early vascular change that evolves in response to ventricular systolic dysfunction. CONCLUSIONS Considering the early appearance of these findings, the resultant impaired power transfer and reduced conduit vessel compliance likely contribute to the progression of abnormal myocardial energetics and systolic dysfunction characteristic of ventricular failure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference51 articles.

1. Aortic input impedance in cardiovascular disease

2. Vascular load defined by the aortic input impedance spectrum;Nichols WW;Fed Proc.,1980

3. Aortic Input Impedance during Nitroprusside Infusion

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3