Use of radiofrequency current to ablate accessory connections in children.

Author:

Dick M1,O'Connor B K1,Serwer G A1,LeRoy S1,Armstrong B1

Affiliation:

1. Division of Pediatric Cardiology, C.S. Mott Children's Hospital, Ann Arbor, MI 48109-0204.

Abstract

BACKGROUND Several investigators have recently ablated electrophysiologically mapped accessory connections in the adult human myocardium by using radiofrequency current. To examine the effectiveness and safety of radiofrequency current for ablation of accessory connections in children, 20 consecutive patients (age, 3-18 years) with preexcitation and/or supraventricular tachycardia were evaluated by electrophysiological study. METHODS AND RESULTS Nineteen of the 20 patients were completely studied and demonstrated accessory connections. After identification of the earliest retrograde atrial activation site, a steerable 7F catheter (with a 4-mm-long electrode at the distal tip) was placed within the ventricular cavity ipsilateral to the accessory connection and positioned at the atrioventricular valve annulus directly opposite the earliest point of retrograde atrial activation. Radiofrequency current was delivered at 50-65 volts for 10-60 seconds at a frequency of 500 kHz. Radiofrequency pulses were delivered for two to 26 trials. Upon completion of radiofrequency trials, repeat electrophysiological testing was performed. Thirteen of 19 subjects (68%) experienced definite successful ablation of their accessory pathway; an additional patient had probable successful ablation, yielding an overall success rate of 74%. Eighty-seven percent of individuals with a left-sided pathway had permanent ablation and 100% with a manifest left-sided pathway experienced successful ablation. Only 29% of the first seven patients had a successful result; in contrast, 92% of the next 12 patients had successful interruption of their accessory pathways. After ablation, 4-day continuous electrocardiographic telemetry disclosed no significant arrhythmias. CPK enzyme rises peaked at 12-24 hours. The rise was excessive and associated with general anesthesia in five patients. The isoenzyme MB fraction rose mildly in five other patients and returned to normal within 72 hours. No clinical or electrocardiographic evidence of myocardial ischemia was detected. Follow-up for 4-12 months indicates no return of preexcitation or tachycardia in any patient whose accessory connection was successfully ablated. CONCLUSIONS This experience indicates that radiofrequency current is an effective and safe technique for ablation of accessory connections in children.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 114 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3