Balloon angioplasty with stent implantation in experimental coarctation of the aorta.

Author:

Morrow W R1,Smith V C1,Ehler W J1,VanDellen A F1,Mullins C E1

Affiliation:

1. Department of Pediatrics, Wayne State University, Wilford Hall Medical Center, Lackland AFB, San Antonio, Tex.

Abstract

BACKGROUND Balloon angioplasty of coarctation of the aorta is an effective method of treatment but is complicated by tearing of the aortic intima, formation of aneurysms, and restenosis. Stent placement at the time of balloon dilation could prevent restenosis and could also prevent progression of intimal tears to aneurysms. The purpose of this study was to evaluate the feasibility of balloon dilation and implantation of balloon-expandable stents in an experimental model of coarctation and to examine the effect of stent placement at the site of surgically created stenosis. METHODS AND RESULTS Coarctation of the aorta was surgically produced in 11 juvenile swine. Simultaneous coarctation angioplasty and stent implantation was performed in 10 animals 34 +/- 7.8 days after surgery. Repeat catheterization was performed 59 +/- 6 days after stent implantation. Five animals underwent reexpansion of stents with subsequent follow-up catheterization. Aortic specimens were examined by light microscopy and scanning electron microscopy. Coarctation angioplasty with stent implantation was successful in all, with an increase in coarctation diameter from 46 +/- 8.5% to 90 +/- 12.2% of proximal aortic diameter (P = .0001). Systolic pressure gradient decreased from 32 +/- 19.8 to 0.5 +/- 2.8 mm Hg (P < .001). All stents were patent at follow-up catheterization, with no evidence of intraluminal thrombosis. Reexpansion in five animals increased the stent diameter from a mean of 77.4 +/- 12.1% to 93 +/- 11.0% of proximal aortic diameter (P = .02). Gross examination of aortic specimens demonstrated formation of neointima over the stent wherever the stent struts were in contact with the aortic wall. The stent occupied a subintimal position and produced minimal compression of the underlying media. Medial compression was noted immediately beneath stent struts, but there was no evidence of intimal or medial dissection. CONCLUSIONS Balloon angioplasty with simultaneous implantation of balloon-expandable stents is effective in relieving aortic obstruction in experimental coarctation. Reexpansion of the rigid stent can be performed in an area of surgical aortotomy and coarctation without significant intimal or medial injury. Stent implantation may be useful in preventing restenosis and aneurysm formation after angioplasty of coarctation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 82 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3