Quantitative adenosine 201Tl single-photon emission computed tomography for the early assessment of patients surviving acute myocardial infarction.

Author:

Mahmarian J J1,Pratt C M1,Nishimura S1,Abreu A1,Verani M S1

Affiliation:

1. Department of Internal Medicine, Baylor College of Medicine, Houston, Tex.

Abstract

BACKGROUND We prospectively investigated whether adenosine 201Tl tomography (SPECT) could determine the extent of coronary artery disease, the presence of jeopardized myocardium, and the risk for in-hospital cardiac events in 120 clinically stable patients early (5 +/- 3 days) after myocardial infarction. METHODS AND RESULTS All patients had coronary angiography and SPECT in close proximity. Adenosine SPECT identified 99% of infarct-related arteries and 82% of severely stenosed (> or = 70%) noninfarct arteries. Multivessel disease was accurately predicted in 69% of patients. Sixty-five percent of stenosed noninfarct arteries had matching thallium perfusion defects, and 92% of these were reversible. The specificity of adenosine SPECT was > 90%. Thallium redistribution occurred often within infarct (59%) and noninfarct (92%) zones. The patency status of the arteries, however, did not predict the presence or extent of jeopardized myocardium. The perfusion defect size was larger (p = 0.0001) in patients with (45 +/- 18%) than in those without (22 +/- 15%) in-hospital cardiac events. Furthermore, 90% of patients with events had a > or = 20% perfusion defect compared with only 38% of those without events (p = 0.0001). The positive-predictive accuracy for developing a cardiac event was 70% when the perfusion defect size was > 30%. The ischemic defect also was larger in patients with (19 +/- 14%) than in those without (10 +/- 10%) events (p = 0.001). The positive- and negative-predictive values for developing early postinfarction angina were 43% and 91%, respectively, when the ischemic defect was > 12%. CONCLUSIONS In selected low-risk survivors of myocardial infarction, early quantitative adenosine SPECT is safe and accurate in detecting and localizing coronary stenoses, assessing the extent of jeopardized myocardium, and determining subsequent risk for in-hospital cardiac events.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 77 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3