Mean transit time for the assessment of myocardial perfusion by videodensitometry.

Author:

Pijls N H1,Uijen G J1,Hoevelaken A1,Arts T1,Aengevaeren W R1,Bos H S1,Fast J H1,van Leeuwen K L1,van der Werf T1

Affiliation:

1. Department of Cardiology, St. Radboud Hospital, University of Nijmegen, The Netherlands.

Abstract

The intrinsic limitations of coronary arteriography to predict the physiological effects of coronary obstructions are well known. Therefore, more direct assessments of the functional significance of coronary stenoses are becoming increasingly important. Study of contrast passage by electrocardiogram-triggered digital radiography has been proposed as a way of assessing changes in myocardial perfusion. The main problems in this approach are the limited time for motionless image acquisition, the potential alteration of vascular volume between different states, and the changing flow pattern induced by contrast agents. This has led to empiric substitution of mean transit time (Tmn) by other time parameters and to representation of vascular volume by maximal contrast intensity (Dmax). To avoid these problems, intact dogs were studied during almost motionless image acquisition of 20-25 consecutive paced heart beats obtained with synchronous radiographic pulses. In this way, unequivocal and reproducible determination of Tmn was possible. Constant and maximal vascular volume was created by continuous infusion of dipyridamole, and it was proved that coronary flow in this model was not influenced by contrast injections. Flow in the circumflex artery was measured by a ring mounted and calibrated Doppler probe. In each dog, flow in the circumflex artery was varied by a balloon occluder in 12 small steps (range, 0-174 +/- 42 ml/min). Inverse appearance time (1/Tapp), Dmax, Dmax/Tapp, inverse time of maximal intensity (1/Tmax), and 1/Tmn were calculated and the relations of these parameters to measured flow were investigated. Tmn proved to be the most reliable parameter for this purpose (r = 0.97 +/- 0.02; mean +/- SD), followed by Tmax (r = 0.93 +/- 0.04). Dmax failed to represent vascular volume but, in fact, showed a moderate correlation with flow (r = 0.78 +/- 0.22), as did Tapp (r = 0.64 +/- 0.18, 0.75 +/- 0.27, and 0.59 +/- 0.26 for the three definitions of Tapp used in this study). Dmax/Tapp correlated better with flow than either component separately. Our results indicate that the mean transit time calculated by videodensitometry can be used to accurately assess changes in myocardial perfusion strictly according to the original principles of indicator dilution theory.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference36 articles.

1. BLOOD FLOW MEASUREMENT THROUGH SINGLE CORONARY ARTERIES BY ROENTGEN DENSITOMETRY

2. BLOOD FLOW MEASUREMENT THROUGH SINGLE CORONARY ARTERIES BY ROENTGEN DENSITOMETRY

3. Zierler KL: Circulation times and the theory of indicator dilution methods for determining blood flow and volume in: Handbook of Physiology Section 2: Circulation. Washington DC American Physiological Society vol 1 1962 pp 585-615

4. Application of digital techniques to selective coronary arteriography: Use of myocardial contrast appearance time to measure coronary flow reserve

Cited by 101 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3