Implantation and intermediate-term follow-up of stents in congenital heart disease.

Author:

O'Laughlin M P1,Slack M C1,Grifka R G1,Perry S B1,Lock J E1,Mullins C E1

Affiliation:

1. Division of Pediatric Cardiology, Texas Children's Hospital, Houston.

Abstract

BACKGROUND Balloon-expandable stents (Johnson and Johnson Interventional Systems) have been in use for congenital heart disease since late 1989. They have made possible treatment in previously untreatable branch pulmonary artery stenoses and systemic venous stenosis. The purpose of this report is to detail the results and intermediate-term follow-up of stents used for treatment of congenital heart disease. METHODS AND RESULTS Eighty-five patients underwent placement of 121 stents in Houston and Boston. Fifty-eight patients had stents put in pulmonary arteries, nine had stents in conduits or outflow tracts, and 21 had stents in venous stenoses or narrowed Fontan anastomoses. (Three patients had stents in two locations.) These stent procedures resulted in gradient reduction from 55.2 +/- 33.3 to 14.2 +/- 13.5 mm Hg in pulmonary arteries, from 41.4 +/- 26.0 to 20.7 +/- 17.0 mm Hg in conduits or outflow tracts, and from 9.8 +/- 6.9 to 2.4 +/- 3.1 mm Hg in venous stenoses or Fontan anastomoses. Diameter of narrowings increased from 4.6 +/- 2.3 to 11.3 +/- 3.2 mm in the pulmonary artery, from 8.8 +/- 3.6 to 12.7 +/- 2.6 in conduits, and from 3.8 +/- 2.9 to 11.3 +/- 2.8 in venous stenoses. Follow-up has shown stent fracture in one patient, restenosis in one, and sudden death in one. Recatheterization has been done in 38 patients an average of 8.6 months after stent installation. Compared with immediately postimplant data, there was no significant change in luminal diameter or pressure gradient. Redilation was performed in 14 patients (17 stents) 1 week to 24 months after implantation (mean, 10.2 months), with a small but significant increase in stenosis diameter. CONCLUSIONS We conclude that stent treatment of vascular stenoses in congenital heart disease retains efficacy at medium-term follow-up and offers a much-improved outlook for patients with these lesions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3