Direct comparison of [13N]ammonia and [15O]water estimates of perfusion with quantification of regional myocardial blood flow by microspheres.

Author:

Bol A1,Melin J A1,Vanoverschelde J L1,Baudhuin T1,Vogelaers D1,De Pauw M1,Michel C1,Luxen A1,Labar D1,Cogneau M1

Affiliation:

1. Laboratory for Positron Emission Tomography, University of Louvain, Brussels, Belgium.

Abstract

BACKGROUND Both [13N]ammonia and [15O]water have been used to quantify myocardial blood flow with positron emission tomography using appropriate tracer kinetic models. A direct comparison of the two tracers with radioactive microspheres has not been performed in the same experimental preparation. METHODS AND RESULTS The two tracers have been tested for myocardial blood flow quantification in closed-chest dogs with circumflex coronary stenosis or permanent occlusion at rest and during adenosine-induced hyperemia. [13N]ammonia- and [15O]water-derived myocardial blood flow values have been compared with radiolabeled microspheres. Validation studies consisted of simultaneous measurements of blood flow with positron emission tomography and microspheres over a wide range of flow values. Blood pool and regional tissue activity curves were fitted with a three-compartment model for [13N]ammonia with and without arterial metabolite correction and with a single-tissue-compartment model for [15O]water. A correction for finite-resolution effect before the fit was also applied. In large regions of interest (5 cm3), a good correlation between the microsphere method and [13N]ammonia (with metabolite correction) was obtained (y = 3 + 0.78x, r = 0.94). The correlation with microspheres was slightly better with [15O]water (y = -3 + 0.89x, r = 0.97). Similar correlations were achieved in smaller regions of interest (1 cm3) as well as in akinetic segments and in central infarct regions. CONCLUSIONS Positron emission tomography with appropriate tracer kinetic models using [13N]ammonia and [15O]water provides an accurate quantitative method for measuring regional myocardial blood flow over a wide range of flow values in normally contracting or akinetic canine myocardium in the absence and in the presence of infarction.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 198 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3