Automatic implantable cardioverter/defibrillator discharges and acute myocardial injury.

Author:

Avitall B1,Port S1,Gal R1,McKinnie J1,Tchou P1,Jazayeri M1,Troup P1,Akhtar M1

Affiliation:

1. Cardiac Electrophysiology Laboratory, University of Wisconsin-Milwaukee Clinical Campus.

Abstract

Multiple defibrillations by the automatic implantable cardioverter/defibrillator (AICD) have been reported to result in localized epicardial damage. No data exist, however, regarding whether this damage can be detected in the clinical setting or whether it interferes with the detection of true myocardial infarction. Forty-nine patients who received defibrillations by patch electrodes were studied prospectively. We attempted to document the presence of myocardial injury with the following three commonly used modalities for the detection of myocardial infarction: serial electrocardiographic changes, serial creatine phosphokinase (CPK) and CPK-MB release, and technetium 99m pyrophosphate scanning. Fifteen patients received defibrillations by AICD patches at the time of AICD generator replacement. Nine patients received defibrillations at the time of new AICD lead placement. The average total energy delivered was 85 +/- 29 J. None of these patients had detectable myocardial injury. Ten patients had defibrillations by the AICD patches at the time of bypass operation. One patient in this group developed acute myocardial infarction in the inferior wall after posterior descending coronary bypass operation, as detected by electrocardiogram, 99mTc pyrophosphate scanning, and CPK-MB analysis. Fifteen patients were evaluated for spontaneous AICD discharges. Thirteen had a maximum of five consecutive shocks, and cumulative energy delivered was not greater than 330 J. None of these patients had detectable injury. Two patients had CPK-MB release of 15.3% and 7.5%, respectively. One of these patients had a positive 99mTc pyrophosphate scan. These two patients received 12 and 17 rapid and consecutive AICD discharges, respectively, with cumulative delivered energy of 360 and 510 J, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3