Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty.

Author:

Pijls N H1,van Son J A1,Kirkeeide R L1,De Bruyne B1,Gould K L1

Affiliation:

1. Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands.

Abstract

BACKGROUND Severity of coronary artery stenosis has been defined in terms of geometric dimensions, pressure gradient-flow relations, resistance to flow and coronary flow reserve, or maximum flow capacity after maximum arteriolar vasodilation. A direct relation between coronary pressure and flow, however, may only be presumed if the resistances in the coronary circulation are constant (and minimal) as theoretically is the case during maximum arteriolar vasodilation. In that case, pressure measurements theoretically can be used to predict maximum flow and assess functional stenosis severity. METHODS AND RESULTS A theoretical model was developed for the different components of the coronary circulation, and a set of equations was derived by which the relative maximum flow or fractional flow reserve in both the stenotic epicardial artery and the myocardial vascular bed and the proportional contribution of coronary arterial and collateral flow to myocardial blood flow are calculated from measurements of arterial, distal coronary, and central venous pressures during maximum arteriolar vasodilation. To test this model, five dogs were acutely instrumented with an epicardial, coronary Doppler flow velocity transducer. Distal coronary pressures were measured by an ultrathin pressure-monitoring guide wire (0.015 in.) with minimal influence on transstenotic pressure gradient. Fractional flow reserve was calculated from the pressure measurements and compared with relative maximum coronary artery flow measured directly by the Doppler flowmeter at three different levels of arterial pressure for each of 12 different severities of stenosis at each pressure level. Relative maximum blood flow through the stenotic artery (Qs) measured directly by the Doppler flowmeter showed an excellent correlation with the pressure-derived values of Qs (r = 0.98 +/- 0.01, intercept = 0.02 +/- 0.03, slope = 0.98 +/- 0.04), of the relative maximum myocardial flow (r = 0.98 +/- 0.02, intercept = 0.26 +/- 0.07, slope = 0.73 +/- 0.08), and of the collateral blood flow (r = 0.96 +/- 0.04, intercept = 0.24 +/- 0.07, slope = -0.24 +/- 0.06). Moreover, the theoretically predicted constant relation between mean arterial pressure and coronary wedge pressure, both corrected for venous pressure, was confirmed experimentally (r = 0.97 +/- 0.03, intercept = 9.5 +/- 13.3, slope = 4.4 +/- 1.2). CONCLUSIONS These results provide the experimental basis for determining relative maximum flow or fractional flow reserve of both the epicardial coronary artery and the myocardium, including collateral flow, from pressure measurements during maximum arteriolar vasodilation. With a suitable guide wire for reliably measuring distal coronary pressure clinically, this method may have potential applications during percutaneous transluminal coronary angioplasty for assessing changes in the functional severity of coronary artery stenoses and for estimating collateral flow achievable during occlusion of the coronary artery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 984 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3