BACKGROUND The purpose of this study was to describe a new technique for catheter ablation of the atrioventricular junction using radiofrequency energy delivered in the left ventricle. METHODS AND RESULTS Catheter ablation of the atrioventricular (AV) junction using a catheter positioned across the tricuspid annulus was unsuccessful in eight patients with a mean +/- SD age of 51 +/- 19 years who had AV nodal reentry tachycardia (three patients), orthodromic tachycardia using a concealed midseptal accessory pathway, atrial tachycardia, atrial flutter (two patients), or atrial fibrillation. Before attempts at catheter ablation of the AV junction, each patient had been refractory to pharmacological therapy, and four had failed attempts at either catheter modification of the AV node using radiofrequency energy or surgical and catheter ablation of the accessory pathway. Conventional right-sided catheter ablation of the AV junction using radiofrequency energy in six patients and both radiofrequency energy and direct current shocks in two patients was ineffective. The mean amplitude of the His bundle potential recorded at the tricuspid annulus at the sites of unsuccessful AV junction ablation was 0.1 +/- 0.08 mV, with a maximum His amplitude of 0.03-0.28 mV. A 7F deflectable-tip quadripolar electrode catheter with a 4-mm distal electrode was positioned against the upper left ventricular septum using a retrograde aortic approach from the femoral artery. Third-degree AV block was induced in each of the eight patients with 20-36 W applied for 15-30 seconds. The His bundle potential at the sites of successful AV junction ablation ranged from 0.06 to 0.99 mV, with a mean of 0.27 +/- 0.32 mV. There was no rise in the creatine kinase-MB fraction and no complications occurred. An intrinsic escape rhythm of 30-60 beats/min was present in seven of the eight patients. Each patient received a permanent pacemaker and has been asymptomatic during 3-13 months of follow-up. CONCLUSIONS Catheter ablation of the AV junction can be achieved effectively and safely using radiofrequency energy delivered in the left ventricle when the conventional right-sided approach is unsuccessful.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference12 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3