Balloon angioplasty for recurrent coarctation of aorta. Immediate and long-term results.

Author:

Hijazi Z M1,Fahey J T1,Kleinman C S1,Hellenbrand W E1

Affiliation:

1. Department of Pediatrics and Pediatric Cardiology, Yale University School of Medicine, New Haven, Conn. 06510.

Abstract

BACKGROUND As angioplasty techniques have been refined and larger low-profile balloons developed, a nonsurgical approach to recoarctation has become available. Several reports have documented both the efficacy and safety of this procedure. However, there are little data available on the long-term follow-up of these patients. This report details the initial results and long-term evaluation of both the relief of obstruction and the presence of hypertension after balloon angioplasty for recurrent coarctation. METHODS AND RESULTS Balloon angioplasty for recurrent coarctation of the aorta was performed 29 times in 26 patients at a median age of 4 years and 9 months (range, 4 months to 29 years), with eight patients less than 1 year old. Initial surgical techniques were end-to-end anastomosis in 11 patients, subclavian flap aortoplasty in 11 patients, and patch aortoplasty in four patients. Angioplasty was performed at a median interval of 2 years and 7 months (range, 4 months to 23 years) after surgery. Mean peak systolic pressure difference across the coarctation decreased from 40.0 +/- 16.8 to 10.3 +/- 9.5 mm Hg (p less than 0.05) after the initial angioplasty, and mean diameter of the aortic lumen at the coarctation site increased from 5.8 +/- 3.5 to 9.0 +/- 4.3 mm (p less than 0.05). There was no mortality, and only one patient developed an aneurysm (4%). Three patients underwent repeat angioplasty for a pressure difference of more than 20 mm Hg. Long-term follow-up is available on 24 of 26 patients with a mean follow-up of 42 +/- 24 months (range, 12-88 months). Mean peak systolic pressure difference across the area of coarctation decreased from 40.3 +/- 17.4 before angioplasty to 8.5 +/- 8.3 mm Hg after final angioplasty (p less than 0.05) and 7.5 +/- 7.5 mm Hg at follow-up. Mean peak systolic blood pressure in the upper extremities decreased from 133.1 +/- 14.9 before angioplasty to 111.1 +/- 14.1 mm Hg at long-term follow-up (p less than 0.05). CONCLUSIONS Balloon angioplasty should be considered the treatment of choice for relief of recurrent aortic coarctation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 92 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3