Multiplexing studies of effects of rapid atrial pacing on the area of slow conduction during atrial flutter in canine pericarditis model.

Author:

Shimizu A1,Nozaki A1,Rudy Y1,Waldo A L1

Affiliation:

1. Department of Medicine, Case Western Reserve University/University Hospitals of Cleveland, Ohio 44106.

Abstract

BACKGROUND We report that rapid atrial pacing interrupts atrial flutter when the orthodromic wave front from the pacing impulse is blocked in an area of slow conduction in the reentry circuit. To characterize the area of slow conduction during atrial flutter and rapid pacing, we studied 11 episodes of induced atrial flutter, mean cycle length 157 +/- 20 msec, in eight dogs with sterile pericarditis. METHODS AND RESULTS Atrial electrograms were recorded simultaneously from 95 pairs of right atrial electrodes during the interruption of atrial flutter by rapid atrial pacing, mean cycle length 139 +/- 21 msec. Areas of slow conduction during atrial flutter were demonstrated at one to three sites in the reentry circuit. After rapid pacing captured the reentry circuit, one area of slow conduction either disappeared (10 episodes) or the degree of slow conduction in an area of slow conduction decreased (one episode). Both changes were in association with activation of the region by a wave front from the pacing impulse that arrived from a direction different than that during the induced atrial flutter. Interruption of atrial flutter during rapid pacing occurred when the orthodromic wave front from the pacing impulse blocked in an area of slow conduction that had either newly evolved during rapid pacing (seven episodes) or that was previously present (four episodes). CONCLUSIONS Areas of slow conduction present during atrial flutter and rapid pacing of atrial flutter are functional and depend on both the atrial rate and the direction of the circulating wave fronts. Interruption of atrial flutter by rapid pacing results from block of the orthodromic wave front of the pacing impulse in an area of slow conduction in the reentry circuit.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 55 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3