Quantitative Radiocardiography

Author:

LEWIS M. L.1,GIUNTINI C.1,DONATO L.1,HARVEY R. M.1,COURNAND A.1

Affiliation:

1. From the Department of Medicine, Columbia University, College of Physicians and Surgeons and the Cardio-Pulmonary Laboratory of the First Medical and Chest Services, Columbia University Division, Bellevue Hospital, New York, New York.

Abstract

The method of quantitative radiocardiography has been applied to the study of cardiac output, right ventricular and pulmonary blood volume in cardiovascular normals, emphysematous subjects, and patients with various types of heart disease. The values of blood flow obtained by means of this technic have been compared with those measured simultaneously by the direct Fick method. A linear correlation has been demonstrated between Q RIHSA and Q Fick , with a regression coefficient of 1.0395 ± 0.0566, when appropriate correction has been made for the contribution of activity in the paracardiac tissues. The principle of the measurement of right ventricular rate of emptying from the fractional decay rate of the precordial counting during the passage of the indicator through the right heart has been validated. The right ventricle behaves essentially as a mixing chamber; a constant fraction of its volume is ejected with each systole. The variability of the emptying rate does not exceed the limits expected on the grounds of statistics of radioactive measurements in normal and in cardiac patients. The significance of the variability observed in emphysematous patients has been discussed. The measured ventricular rates of emptying are reproducible in repeated curves recorded after injection of RIHSA or dissolved Kr 85 ; are little affected by change of the position of the tip of the injecting catheter; or by small changes in the position of the collimator. The right ventricular end-diastolic and residual volumes have been found to average 221 ± 50 ml. and 128 ± 34 ml. respectively, in 18 normal subjects. The calculated pulmonary blood volume in 18 normal subjects averages 313 ± 58 ml./M. 2 The significance of this value and the possible extreme range of error resulting from the method have been assessed.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference21 articles.

1. DONAT o, L., ROCHESTER , D. F. , LE wis, M. L., DURAND , J. , PARKER , J. 0., AND HARVEY, R. M.: Quantitative radiocardiography. II. Technic and analysis of curves. Circulation 26 : 183 , 1962 .

2. The Cerebral Blood Flow in Man Determined by the Use of Radioactive Krypton

3. The determination of cardiac output by the dilution method without arterial sampling;PRITCHARD W. H.;J. Lab. & Clin. Med.,1955

Cited by 62 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Pulmonary Hemodynamics;Comparative Biology of the Normal Lung;2015

2. Clinical Applications of Quantitative Radiocardiography;Acta Medica Scandinavica;2009-04-24

3. Clinical Applications of Quantitative Radiocardiography;Acta Medica Scandinavica;2009-04-24

4. Quantitation;Clinical Nuclear Medicine;1998

5. Suggested Reference Values for Regional Blood Volumes in Humans;Health Physics;1991-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3