Author:
St John Sutton M G,Hagler D J,Tajik A J,Giuliani E R,Seward J B,Ritter D G,Ritman E L
Abstract
Computer analysis of the M-mode echocardiogram in 50 normal newborns provided measurements of wall thicknesses and chamber size and, in addition, assessment of right and left ventricular wall, septal, and cavity dynamics throughout the cardiac cycle. Data obtained with this new technique indicated that (1) right and left ventricular cavity functions are similar in the normal newborn, (2) right and left ventricular cavity filling and emptying vary directly with peak rates of septal and ventricular wall thinning and thickening, respectively, and (3) there is a close time relationship among maximum left atrial dimension, minimum left ventricular dimension, and mitral valve opening. This analysis, which is the first complete analysis of the echocardiogram in the newborn, provides a normal range of septal and ventricular wall dynamics as well as right and left ventricular and left atrial function and has clinical implications in that it may allow early recognition of both congenital and perinatal myocardial disease.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Reference10 articles.
1. Echocardiography in the Diagnosis of Congenital Heart Disease
2. Solinger RE Elbl F Minhas K: Echocardiography in congenital heart disease in neonates and infants. (abstr) Circulation 44 (suppl II): 11-228 1971
3. Goldberg SJ Allen HD Sahn DJ: Pediatric and Adolescent Echocardi ography: A Handbook. Chicago Year Book Medical Publishers 1975
Cited by
21 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献