Technetium stannous pyrophosphate myocardial scintigrams in patients with chest pain of varying etiology.

Author:

Willerson J T,Parkey R W,Bonte F J,Meyer S L,Atkins J M,Stokley E M

Abstract

Technetium-99m stannous pyrophosphate was utilized for myocardial imaging in 202 patients admitted to the hospital with chest pain of uncertain etiology. One hundred and one patients had clinical and evolved electrocardiographic and enzymatic evidence of acute myocardial infarction. Ninety-six of these 101 patients had increased myocardial uptake of the technetium stannous pyrophosphate and positive myocardial scintigrams; there was nearly precise correlation between the ECG and myocardial imaging localization of the area of infarction for acute transmural myocardial infarctions. In the five patients with negative myocardial images the scintigrams were obtained after seven or more days had elapsed following the myocardial infarction. In the remaining 101 patients no clinical, ECG, or enzymatic evidence of infarction developed; 92 of these patients had negative myocardial scintigrams. Seven of the remaining nine patients were admitted with "unstable angina pectoris", and despite the absence of diagnostic ECG and enzyme evolution each of these patients had faintly and diffusely positive myocardial scintigrams. The remaining two patients had positive myocardial scintigrams but no definite ECG or enzymatic evidence of acute myocardial infarction. Thus the technetium pyrophosphate imaging technique appears safe, inexpensive and to correlate well with ECG and enzyme identification of the presence of infarction and with ECG localization of myocardial infarction. In addition the positive myocardial scintigrams in some patients with "unstable angina" suggest that there may be limited myocardial necrosis that is ordinarily undetected by ECG and enzymes in these patients. The incidence of false positive and false negative scintigrams appears to be small.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference17 articles.

1. Improvement in Myocardial Function and Coronary Blood Flow in Ischemic Myocardium after Mannitol

2. Temporal changes in collateral coronary blood flow in ischemic myocardium during intraaortic balloon pumping;Circulation,1974

Cited by 219 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3