Author:
Aranda J,Castellanos A,Moleiro F,Befeler B
Abstract
His bundle recordings were studied in four patients with short P-R and A-H intervals, and narrow QRS complexes, who had experienced several episodes of supraventricular tachyarrhythmias. The heart was paced from the high right atrium (HRA) and the coronary sinus (CS). In three patients the A-H Wenckebach phenomenon occurred at higher rates (greater than 200 pacing beats/min) when the CS was paced than when pacing was performed from the HRA. Moreover, CS stimulation produced smaller increments in the A-H interval than did pacing from HRA. The extrastimulus method of testing was done. In cases 1 and 2 the functional refractory period of the A-H tissues was 15 to 25 msec shorter during CS pacing than when pacing from the HRA. In case 3, the low right atrium (LRA) as well as the other two sites were paced. A type 1 gap was seen from HRA, a type 2 gap from CS, and both types appeared when the LRA was paced. Case 4, in which the mid-right atrium (MRA) was also stimulated, had a double pathway from HRA and CS with conduction through the accessory pathway late in the cycle and through the A-V node earlier in the cycle. However, the A-V node could not be penetrated during MRA stimulation. It appeared that the pacing site influenced the A-H conduction pattern and refractoriness, possibly by changing the site and/or mode of entry of the stimulus into the pathways that are responsible for this syndrome.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Cited by
43 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献