Echocardiographic evaluation of intracardiac pacing catheters: M-mode and two-dimensional studies.

Author:

Reeves W C,Nanda N C,Barold S S

Abstract

Thirty patients with right ventricular (RV) and 15 with coronary sinus (CS) pacing catheters were studied by M-mode echocardiography. RV catheters, detected in 23, appeared as linear echoes in the right ventricle during mitral valve recordings in 12, adjacent or superimposed on the tricuspid valve (TV) in 14, and immediately anterior to aortic root and pulmonary valve echoes in two with a redundant loop in RV outflow. In three with complete heart block, prominent systolic anterior movements of the TV occurred when atrial systole coincided with ventricular systole, probably due to catheter-induced TV "buckling" or exaggerated TV annular motion. Catheter echoes mimicked TV recordings in three, since its motion pattern was similar, although delayed and mimicked prolapsing right atrial myxomas in two because of multilayered complexes behind TV, while reverberations cluttering the left ventricle simulated structural echoes present in that cavity. CS catheters, detected in 14 as linear echoes in the area of atrial septum recorded behind the TV, showed typical small humps in late diastole/early systole. Cross-sectional echocardiography with a mechanical sector scanner demonstrated RV catheters at the RV apex in five of seven patients, while CS catheters were detected near the base of the atrial septum in three of five patients. Echocardiography has the potential to localize pacing catheters which are occasionally difficult radiologically or electrocardiographically. Failure to recognize catheter echo patterns may result in errors in echocardiographic interpretation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference12 articles.

1. Echocardiographic interpretation in the presence of Swan-Ganz intracardiac catheters

2. Echocardiography of pacing catheters. (abstr) Cl;Nanda NC;Res,1977

3. Echocardiography of the inter-atrial septum;Nanda NC;Ultrasound in Med,1976

4. Ventricular Pacemaker Wire Simulating a Right Atrial Mass

5. Abnormal systolic anterior motion of atrio-ventricular valves in complete heart block;Nanda NC;Ultrasound in Med,1977

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3