The echocardiogram of the anterior leaflet of the mitral valve. Correlation with hemodynamic and cineroentgenographic studies in dogs.
-
Published:1975-01
Issue:1
Volume:51
Page:88-97
-
ISSN:0009-7322
-
Container-title:Circulation
-
language:en
-
Short-container-title:Circulation
Author:
Pohost G M,Dinsmore R E,Rubenstein J J,O'Keefe D D,Grantham R N,Scully H E,Beierholm E A,Frederiksen J W,Weisfeldt M L,Daggett W M
Abstract
The echocardiogram of the anterior leaflet of the mitral valve (ECHO) was compared to hemodynamic and cineroentgenographic data to evaluate its accuracy in timing mitral valve (MV) opening and closure, and to validate it as an indicator of MV motion. The ECHO, high speed cineroentgenography at 250 frames/sec, and/or measurement of intracardiac pressures allowed accurate timing of the events of MV motion in dogs on right heart bypass. The intersection of left ventricular and left atrial pressures in early diastole preceded the onset of rapid anterior motion of ECHO (D' point) by 17 to 33 plus or minus 7.6 msec; r equals 0.98. The onset of left ventricular systole occurred before the termination of final rapid posterior motion of the ECHO in end diastole (Co point) by 25 plus or minus 10 msec; r equals 0.96. Radiopaque clips were attached to the free edges of both leaflets of the MV. Cineroentgenographically determined plots of clip distance from the ultrasound transducer were morphologically similar to the simultaneously recorded ECHO. A delay of 23 plus or minus 3 (0 to 40) msec was observed in the ECHO peaks of diastolic anterior excursion compared to clip motion. Contrast medium advances beyond the free edges of MV leaflets mixing with left ventricular blood 43 plus or minus 3 msec after initial separation. These cineroentgenographic studies elucidate nonuniformity of leaflet motion responsible for ECHO delays. Thus, ECHO D' and Co correlate well with hemodynamic indicators of MV opening and closure. However, ECHO motion, although qualitatively similar, is unpredictably delayed compared to cineroentgenography of clips on the MV free edge. Since the ECHO correlates well with hemodynamic indices of MV opening and closure, this noninvasive technique can be used as a reference in the timing of intracardiac events and in the determination of systolic and diastolic time intervals.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Reference22 articles.
1. com.atypon.pdfplus.internal.model.plusxml.impl.AuthorGroup@72ee979
. Philadelphia Lea & Febiger 1972
2. Ultrasound Cardiography: Contrast Studies in Anatomy and Function
3. Applications of ultrasound in cardiology and cardiovascular physiology
4. com.atypon.pdfplus.internal.model.plusxml.impl.AuthorGroup@48d40dd7
: Mitral and aortic valve movements recorded by an ultra-sonic echo method. An experimental study. In Ultrasound Cardiology. Acta Med Scand 370 (suppl): 68 1961
Cited by
67 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献