The echocardiogram of the anterior leaflet of the mitral valve. Correlation with hemodynamic and cineroentgenographic studies in dogs.

Author:

Pohost G M,Dinsmore R E,Rubenstein J J,O'Keefe D D,Grantham R N,Scully H E,Beierholm E A,Frederiksen J W,Weisfeldt M L,Daggett W M

Abstract

The echocardiogram of the anterior leaflet of the mitral valve (ECHO) was compared to hemodynamic and cineroentgenographic data to evaluate its accuracy in timing mitral valve (MV) opening and closure, and to validate it as an indicator of MV motion. The ECHO, high speed cineroentgenography at 250 frames/sec, and/or measurement of intracardiac pressures allowed accurate timing of the events of MV motion in dogs on right heart bypass. The intersection of left ventricular and left atrial pressures in early diastole preceded the onset of rapid anterior motion of ECHO (D' point) by 17 to 33 plus or minus 7.6 msec; r equals 0.98. The onset of left ventricular systole occurred before the termination of final rapid posterior motion of the ECHO in end diastole (Co point) by 25 plus or minus 10 msec; r equals 0.96. Radiopaque clips were attached to the free edges of both leaflets of the MV. Cineroentgenographically determined plots of clip distance from the ultrasound transducer were morphologically similar to the simultaneously recorded ECHO. A delay of 23 plus or minus 3 (0 to 40) msec was observed in the ECHO peaks of diastolic anterior excursion compared to clip motion. Contrast medium advances beyond the free edges of MV leaflets mixing with left ventricular blood 43 plus or minus 3 msec after initial separation. These cineroentgenographic studies elucidate nonuniformity of leaflet motion responsible for ECHO delays. Thus, ECHO D' and Co correlate well with hemodynamic indicators of MV opening and closure. However, ECHO motion, although qualitatively similar, is unpredictably delayed compared to cineroentgenography of clips on the MV free edge. Since the ECHO correlates well with hemodynamic indices of MV opening and closure, this noninvasive technique can be used as a reference in the timing of intracardiac events and in the determination of systolic and diastolic time intervals.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference22 articles.

1. com.atypon.pdfplus.internal.model.plusxml.impl.AuthorGroup@72ee979 . Philadelphia Lea & Febiger 1972

2. Ultrasound Cardiography: Contrast Studies in Anatomy and Function

3. Applications of ultrasound in cardiology and cardiovascular physiology

4. com.atypon.pdfplus.internal.model.plusxml.impl.AuthorGroup@48d40dd7 : Mitral and aortic valve movements recorded by an ultra-sonic echo method. An experimental study. In Ultrasound Cardiology. Acta Med Scand 370 (suppl): 68 1961

Cited by 67 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Hemodynamics-driven mathematical model of first and second heart sound generation;PLOS Computational Biology;2021-09-22

2. What Is the Heart? Anatomy, Function, Pathophysiology, and Misconceptions;Journal of Cardiovascular Development and Disease;2018-06-04

3. Anatomy of the Mitral Apparatus;Percutaneous Treatment of Left Side Cardiac Valves;2017-08-22

4. Ventricular structure–function relations in health and disease: Part I. The normal heart;European Journal of Cardio-Thoracic Surgery;2014-08-01

5. A simplified model for mitral valve dynamics;Computer Methods and Programs in Biomedicine;2013-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3