Author:
Macmanus Q,Grunkemeier G,Thomas D,Lambert L E,Starr A
Abstract
The Starr-Edwards model 6000 mitral valve was the first successful mitral prosthesis. A fifteen year follow-up of 110 patients undergoing isolated mitral valve replacement with this prosthesis from 1960 to 1966 is presented. There were 22 (20%) operative and 37 (42%) late deaths at a mean of 8.6 years postoperatively. Preoperative variables leading to late death and thromboembolism are analyzed. Seventeen of 25 operative survivors had improvement in their NYHA Functional Class status and eight other remained unchanged an average of 13.1 years after surgery. There are 5000 patients world-wide currently relying on this prosthesis. Despite a high rate of thromboembolism in the past, elective replacement is not recommended except in selected patients.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Reference6 articles.
1. Mitral Replacement
2. Mitral replacement;Starr A;J Thorac Cardiovasc Surg,1967
3. Mitral valve replacement with ball valve prostheses
4. Starr A Grunkemeier G Lambert L Okies JE Thomas D: Mitral valve replacement. A 10 year follow-up of non-cloth-covered versus clothcovered caged-ball prosthesis. Circulation 54 (suppl III): III-47 1976
Cited by
21 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献