Pulsatile Hemodynamics in Congestive Heart Failure

Author:

Mitchell Gary F.1,Tardif Jean-Claude1,Arnold J. Malcolm O.1,Marchiori Gordon1,O’Brien Terrence X.1,Dunlap Mark E.1,Pfeffer Marc A.1

Affiliation:

1. From Cardiovascular Engineering Inc (G.F.M.), Holliston, Mass; Montreal Heart Institute (J.-C.T.), Montreal, Quebec, Canada; London Health Sciences Center (J.M.O.A., G.M.), London, Ontario, Canada; Ralph H. Johnson VA Medical Center (T.X.O.), Charleston, SC; Louis Stokes VA Medical Center (M.E.D.), Cleveland, Ohio; and Brigham and Women’s Hospital (M.A.P.), Boston, Mass.

Abstract

Pulse pressure, an indirect measure of vascular stiffness and pulsatile load, predicts clinical events in congestive heart failure (CHF), suggesting that abnormal pulsatile load may contribute to CHF. This study was designed to assess more direct measures of central pulsatile load in CHF. Noninvasive hemodynamic evaluations were performed in 28 subjects with CHF and 40 controls using calibrated tonometry of the brachial, radial, femoral, and carotid arteries along with echocardiographic assessment of left ventricular outflow tract (LVOT) diameter and Doppler flow. Characteristic impedance (Z c ) was calculated as the ratio of ΔP (carotid) and ΔQ (LVOT flow) in early systole. Carotid-radial (CR-PWV) and carotid-femoral (CF-PWV) pulse wave velocities were calculated from tonometry. Augmentation index was assessed from the carotid waveform. Total arterial compliance (TAC) was calculated using the area method. Brachial pulse pressure was elevated (62±16 versus 53±15 mm Hg, P =0.015) in CHF because of lower diastolic pressure (66±10 versus 73±9 mm Hg, P =0.003). CHF had higher Z c (225±76 versus 184±66 dyne · sec · cm −5 , P =0.020). CF-PWV did not differ (9.7±2.7 versus 9.2±2.0, P =0.337), whereas CR-PWV was lower in CHF (8.6±1.4 versus 9.4±1.5, P =0.038). There was no difference in TAC (1.4±0.5 versus 1.4±0.6 mL/mmHg, P =0.685), and augmentation index was lower in CHF (8±17 versus 21±13%, P =0.001). CHF subjects have elevated central pulsatile load (Z c ), which is not apparent in global measures such as augmentation index or TAC, possibly because of contrasting changes in central and peripheral conduit vessels. This increased pulsatile load represents an important therapeutic target in CHF.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Cited by 176 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3