Continuous vs intermittent blood pressure measurements in estimating 24-hour average blood pressure.

Author:

di Rienzo M,Grassi G,Pedotti A,Mancia G

Abstract

In the past few years noninvasive automatic blood pressure (BP) recorders have been increasingly used to estimate patients' 24-hour BP more accurately than by one or few isolated measurements. However, these recorders only allow BP to be intermittently measured at intervals between 5 to 30 minutes, which means that the number of values collected over 24 hours (10 to 100) remains a tiny fraction of the thousands of values that occur during the same period. To determine whether this represents a limitation to this approach, BP was recorded intraarterially for 24 hours (Oxford method) in 20 ambulant hypertensive patients. A beat-to-beat analysis of the BP recording was provided by a computer, and the average 24-hour systolic, diastolic, and mean BP values were compared with those obtained by analyzing single BP waves of the same recording at intervals of 5, 10, 15, 30, and 60 minutes. In each subject the average 24-hour BP values obtained by the beat-to-beat analysis closely corresponded to those obtained by the analysis performed at 5-, 10-, 15-, or 30-minute intervals. In most subjects, this was the case also when the analysis was performed at 60-minute intervals. These findings demonstrate that intermittency of measurements does not limit the accurate assessment of true average BP. Indeed, accurate assessment can be achieved at intervals as much as 30 or 60 minutes apart.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Reference18 articles.

1. Variation in arterial pressure throughout the day and night;Richardson DW;Clin Sci,1964

2. Variability of automatic blood pressure measurements over 24 hour periods;Athanassiadis D;Clin Sci,1969

3. Value of prolonged recording of blood pressure in assessment of hypertension.

4. The representative blood pressure: usefulness of office, basal, home and ambulatory readings;Perloff D;Cardiovasc Med,1978

5. Contribution of ambulatory blood pressure to the assessment of patients with mild to moderate elevation of office blood pressure;Sokolow M;Cardiovasc Reviews and Reports,1980

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3