Effects of Aortic Regurgitation on Left Ventricular Performance

Author:

MORROW ANDREW G.1,BRAWLEY ROBERT K.1,BRAUNWALD EUGENE1,Seipp Harry W.1,Cobb David E.1,Montgomery Maxine P.1

Affiliation:

1. From the Clinic of Surgery and Cardiology Branch, National Heart Institute, Bethesda, Maryland.

Abstract

The volume of regurgitant blood flow and its effects on the performance of the left ventricle were assessed at operation in 14 patients with varying degrees of aortic regurgitation. Instantaneous forward and regurgitant flows in the ascending aorta were measured with a sine-wave electromagnetic flowmeter simultaneously with left ventricular and aortic pressures. In eight patients who had aortic regurgitation without associated stenosis, 63 to 75% of the total forward stroke volume regurgitated during the succeeding diastole. The calculated regurgitant orifice areas ranged from 0.13 to 0.44 cm 2 /m 2 . After replacement of the aortic valve with a Starr-Edwards prosthesis, the absence of regurgitant flow was proved in every patient, and the records of aortic blood flow closely resembled those seen in patients with normal aortic valves. Net forward blood flow increased by an average of 60%, total left ventricular stroke volume fell 42%, and the mean aortic pressure rose 29%. The pressure work of the left ventricle was elevated preoperatively in five of the eight patients (average 89 g-m/stroke/m 2 ) and fell significantly to an average of 34 g-m/stroke/m 2 after valve replacement. Kinetic ventricular work was high in seven of the eight patients and comprised 10% of total work before replacement but only 4.8% afterward. Similar observations were made in five patients with aortic stenosis and associated aortic regurgitation, ranging in severity from 24 to 72% of total forward stroke volume. In four patients in whom the valve was replaced, no residual regurgitation was present afterward, and net forward flow rose an average of 49%. Kinetic left ventricular work was extremely high in every patient and averaged 26% of total work preoperatively and 13% after valve replacement. In this group, pressure work was variable both before and after operation. The studies described provide definitive information concerning the effects of aortic valve disease on left ventricular performance in man and document the favorable changes in flow, pressure, and left ventricular work which immediately follow aortic valve replacement.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3