The Use of Fiberoptics in Clinical Cardiac Catheterization

Author:

GAMBLE WALTER J.1,HUGENHOLTZ PAUL G.1,MONROE R. GRIER1,POLANYI MICHAEL1,NADAS ALEXANDER S.1

Affiliation:

1. From the Cardiopulmonary Laboratory, Children's Hospital Medical Center; the Department of Pediatrics, Harvard Medical School, Boston, Massachusetts.

Abstract

Intracardiac blood oxygen saturation was determined in 31 patients, at cardiac catheterization, by means of a fiberoptic in vivo hemoreflection system, giving an immediate report. When compared to in vitro spectrophotometric analysis of samples obtained through a second catheter, a standard error of estimate of only 1.99-per cent saturation (r = 0.966) was found for the higher speed instrument (response time 0.07 second) and 1.13-per cent saturation (r = 0.992) for the slower instrument (response time 1.5 seconds). The average of the standard deviations of saturation values in cardiac chambers in which no primary mixing occurred, was only 0.88-per cent saturation. The continuous recording of oxygen saturation while moving the catheter, permits measurements at multiple sites within a brief period of time (14 to 26 seconds through the right side of the heart). Oxygen saturation changes can be continuously monitored under changing conditions, such as exercise. Finally, the higher speed instrument permits investigation of changes in oxygen saturation in patients with congenital heart disease within portions of the cardiac cycle.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference27 articles.

1. Determination of gases in blood and other solutions lby vacuum extraction and manometric measurement;VAN SLYKE D. D.;J. Biol. Chem.,1924

2. Routine use of ultramicro methods in the clinical laboratory;NATELSON S.;Am. J. Clin. Path.,1951

3. Spectrophotometric Determination of Hemoglobin and Oxyhemoglobin in Whole Hemolyzed Blood

4. WOOD E. H.: The oximeter. In Glasser O. Ed.: Medical Physics. Ed. 2. Chicago Year Book Publisher Inc. 1950.

5. ZIJLSTRA W. G.: A Manual of Reflection Oximetry. Netherlands Van Corcum & Co. Assen. 1955.