Experimental Demonstration of Concealed AV Conduction in the Human Heart

Author:

LANGENDORF R.1,PICK A.1,EDELIST A.1,KATZ L. N.1

Affiliation:

1. From the Cardiovascular Institute, Michael Reese Hospital and Medical Center, Chicago, Illinois.

Abstract

Artificial pacing of patients with Stokes-Adams disease provided an opportunity to study experimentally the ways of operation of concealed antegrade or retrograde conduction, or both, in the AV junction. With a catheter electrode in the right atrium the classical experiment of Lewis and Master was repeated, revealing, during a 2:1 ventricular response to an atrial tachycardia, the delaying effect of seemingly blocked atrial impulses on subsequent AV conduction. Shifting the position of a single premature atrial impulse within a constant driving cycle of the atria produced graded effects of "blocked" atrial impulses on AV junctional refractoriness, permitting an estimation of the duration of the "phase of concealed AV conduction." Interpolation of such premature atrial impulses into successive driving cycles resulted in "repetitive concealed conduction." In an artificially produced atrial parasystole there was observed "concealed discharge" of a subsidiary (escaping) AV junctional pacemaker by an apparently nonconducted atrial impulse. With a catheter electrode in the right ventricle in a case of advanced AV block, concealed retrograde conduction of pacer stimuli disturbed the rhythmicity of a spontaneous AV junctional pacemaker. In a case of advanced AV block with preserved retrograde conduction (unidirectional block), evidence of penetration of the upper AV junction by the "blocked" antegrade impulse was found. With electrodes implanted in the left ventricle in a case of advanced AV block, concealed retrograde conduction of the artificial pacemaker stimuli enhanced antegrade conduction by transiently changing an area of unidirectional block to one of supernormal conduction. Thus, all known manifestations of concealed atrioventricular and ventriculo-atrial conduction, occurring spontaneously in clinical records or induced in animal experiments, were artificially reproduced in the human heart.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference23 articles.

1. Concealed A-V conduction: The effect of blocked impulses on the formation and conduction of subsequent impulses

2. Observations upon conduction in the mammalian heart. A-V conduction;LEWIS T.;Heart,1925

3. Concealed Conduction

4. LANGENDORF R. PICK A. AND KATZ L. N.: Ventricular response in atrial fibrillation: The role of concealed conduction in the A-V junction. Cas. 16k. ces. 98: 1596 1959.

Cited by 70 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3