Metabolic Dysfunction in Continuous‐Flow Left Ventricular Assist Devices Patients and Outcomes

Author:

Nguyen Ann B.1,Imamura Teruhiko1,Besser Stephanie1,Rodgers Daniel1,Chung Ben1,Raikhelkar Jayant1,Kalantari Sara1,Smith Bryan1,Sarswat Nitasha1,LaBuhn Colleen2,Jeevanandam Valluvan2,Kim Gene1,Sayer Gabriel1,Uriel Nir1

Affiliation:

1. Section of Cardiology Department of Medicine University of Chicago IL

2. Section of Cardiac Surgery Department of Surgery University of Chicago IL

Abstract

Background Metabolic impairment is common in heart failure patients. Continuous‐flow left ventricular assist devices ( CFLVADs ) improve hemodynamics and outcomes in patients with advanced heart failure; however, the effect of CFLVADs on metabolic status is unknown. This study aims to evaluate the changes in metabolic status following CFLVAD implantation and measure the correlation of metabolic status with outcomes. Methods and Results Prospective data on CFLVAD patients were obtained. Metabolic evaluation, including hemoglobin A1C, free and total testosterone, thyroid‐stimulating hormone ( TSH ), and free T4, was obtained before and at multiple time points following implantation. Patients with nonelevated thyroid‐stimulating hormone and normal hemoglobin A1C and testosterone levels were defined as having normal metabolic status. Baseline characteristics, hemodynamics, and outcomes were collected. One hundred six patients were studied, of which 56 had paired data at baseline and 1‐ to 3‐month follow‐up. Before implantation, 75% of patients had insulin resistance, 86% of men and 39% of women had low free testosterone, and 44% of patients had abnormal thyroid function. There was a significant improvement in hemoglobin A1C, free testosterone, and thyroid‐stimulating hormone following implantation ( P <0.001 for all). Patients with normal hemoglobin A1C (<5.7%) following implantation had higher 1‐year survival free of heart failure readmissions (78% versus 23%; P <0.001). Patients with normal metabolic status following implantation also had higher 1‐year survival free of heart failure readmissions (92% versus 54%; P =0.04). Conclusions Metabolic dysfunction is highly prevalent in advanced heart failure patients and improves after CFLVAD implantation. Normal metabolic status is associated with a significantly higher rate of 1‐year survival free of heart failure readmissions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3