Noninvasive measurement of velocity profiles and blood flow in the common carotid artery by pulsed Doppler ultrasound.

Author:

Keller H M,Meier W E,Anliker M,Kumpe D A

Abstract

A computer-controlled 14-channel pulsed Doppler ultrasound instrument was used as a noninvasive means to evaluate instantaneous velocity profiles and flow in the comlon carotid arteries of 22 healthy persons and in 22 patients. Of the later, 13 had severe obstructions of the extracranial portion of the carotid artery, four had obstruction of the intracranial portion, and five had severe aortic valve insufficiency (AI), with more than 60% regurgitation in all cases. Measurements could be performed within an accuracy of about +/- 20% under clinical conditions and revealed perfusion values of 5 to 8 ml per second (300 to 480 ml per minute) in healthy persons. Of the patients, values less than 3 ml per second (180 ml per minute) were detected in nine, between 3 and 5 mm per second (180 to 300 ml per minute) in four, and normal values in another four, while significant backflow was observed only in patients with severe AI. Consecutive blood flow profiles were recorded every 4 msec; these demonstratedthat, for a period lasting from 40 msec to 280 msec after the initial systolic peak, blood flow decelerated more rapidly in the central portion of the vessel lumen than near the wall. This situation was present in all healthy persons and in most patients with pathological flow. In patients with AI, flow reinversion from reverse to normal began near the vessel wall, while in the middle third of the vessel lumen, blood was still flowing backward. These phenomena seem to be in agreement with the theoretical and experimental findings of Wormersly, Müller, and others. The AI patients who underwent artificial valve implantation were studied ten days after operation and showed no or little backflow in the common carotid artery at that time.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Reference21 articles.

1. Pulsed Ultrasonic Doppler Blood-Flow Sensing

2. de Vlieger M White DN McCready VR (eds): Ultrasonics in Medicine. Proceedings of the Second World Congress 1973. New York American Elsevier Publishing Co 1974

3. Planiol T Pourcelot L: Doppler effect study of the carotid circulation. In de Vlieger M White DN McCready VR (eds); Ultrasonics in Medicine. Proceedings of the Second World Congress 1973. New York American Elsevier Publishing Co pp 104-111 1974

Cited by 70 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ultra-fast ultrasound blood flow velocimetry for carotid artery with deep learning;Artificial Intelligence in Medicine;2023-10

2. Ultrafast Ultrasound Speckle Tracking Using the Dynamical Kernels for Improved Blood Flow Velocity Profiling;2022 IEEE 8th International Conference on Computer and Communications (ICCC);2022-12-09

3. Optimum Speckle Tracking Based on Ultrafast Ultrasound for Improving Blood Flow Velocimetry;IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control;2021-03

4. Taking the pulse of aging: Mapping pulse pressure and elasticity in cerebral arteries with optical methods;Psychophysiology;2014-08-06

5. Physical and Technical Principles of Doppler Sonography;Doppler Sonography in Infancy and Childhood;2014-02-19