Atrial Fibrillation Screening During Routine Automated Office, Home, and Ambulatory Blood Pressure Measurement: A Diagnostic Test Accuracy Systematic Review and Meta-Analysis

Author:

Kyriakoulis Konstantinos G.1ORCID,Kollias Anastasios1ORCID,Menti Ariadni1ORCID,Chardouvelis Panagiotis1,Stergiou George S.1ORCID

Affiliation:

1. Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.

Abstract

BACKGROUND: Atrial fibrillation (AF) is often asymptomatic and undiagnosed. As AF and hypertension often coexist, opportunistic AF detection during routine automated blood pressure (BP) measurement appears to be an attractive screening method. METHODS: A systematic literature search was conducted to identify studies assessing the diagnostic test accuracy of office, home, or 24-hour ambulatory BP measuring devices with AF detection algorithms versus reference electrocardiography. Analyses were performed per participant (AF status based on several BP readings; most office/home devices) or per reading (AF status based on individual readings; all ambulatory devices). A meta-analysis stratified by device type (office/home/ambulatory) was conducted to calculate pooled measures of diagnostic accuracy. Sensitivity/meta-regression analyses were also performed. RESULTS: Among 3096 records initially retrieved, 23 diagnostic test accuracy studies were included. Data derived from 11 093 individuals (weighted age 69 years, males 56%, hypertensives 79%, diabetics 24%, and AF prevalence 17%) indicated a pooled sensitivity 0.97 (95% CI, 0.92–0.99), specificity 0.93 (95% CI, 0.90–0.95), and accuracy 0.93 (95% CI, 0.89–0.95), with generally consistent results using office, home, or ambulatory BP devices (slightly lower specificity with the latter). The positive and negative predictive values were 0.70 (95% CI, 0.60–0.80) and 0.99 (95% CI, 0.98–1.00), respectively. Sensitivity analyses indicated lower specificity in studies implementing reading versus participant analyses. Most studies presented a low risk of bias and minor applicability concerns. CONCLUSIONS: There is considerable and consistent evidence suggesting high diagnostic accuracy of AF detection algorithms implemented in automated BP monitors during routine BP measurements in and out of the office. AF diagnosis requires verification (electrocardiography) before treatment is administered.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3