Indexes of Aortic Pressure Augmentation Markedly Underestimate the Contribution of Reflected Waves Toward Variations in Aortic Pressure and Left Ventricular Mass

Author:

Booysen Hendrik L.1,Woodiwiss Angela J.1,Sibiya Moekanyi J.1,Hodson Bryan1,Raymond Andrew1,Libhaber Elena1,Sareli Pinhas1,Norton Gavin R.1

Affiliation:

1. From the Cardiovascular Pathophysiology and Genomics Research Unit, Schools of Physiology (H.L.B., A.J.W., M.J.S., B.H., A.R., P.S., G.R.N.) and Medicine (E.L.), Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South Africa.

Abstract

Although indexes of wave reflection enhance risk prediction, the extent to which measures of aortic systolic pressure augmentation (augmented pressures [Pa] or augmentation index) underestimate the effects of reflected waves on cardiovascular risk is uncertain. In participants from a community sample (age >16), we compared the relative contribution of reflected (backward wave pressures and the reflected wave index [RI]) versus augmented (Pa and augmentation index) pressure wave indexes to variations in central aortic pulse pressure (PPc; n=1185), and left ventricular mass index (LVMI; n=793). Aortic hemodynamics and LVMI were determined using radial applanation tonometry (SphygmoCor) and echocardiography. Independent of confounders, RI and backward wave pressures contributed more than forward wave pressures, whereas Pa and augmentation index contributed less than incident wave pressure to variations in PPc ( P <0.0001 for comparison of partial r values). In those <50 years of age, while backward wave pressures (partial r =0.28, P <0.0001) contributed more than forward wave pressures (partial r =0.15, P <0.001; P <0.05 for comparison of r values), Pa (partial r =0.13, P <0.005) contributed to a similar extent as incident wave pressure (partial r =0.22, P <0.0001) to variations in LVMI. Furthermore, in those ≥50 years of age, backward wave pressures (partial r =0.21, P <0.0001), but not forward wave pressures ( P =0.98), while incident wave pressure (partial r =0.23, P <0.0001), but not Pa ( P =0.80) were associated with LVMI. Pa and augmentation index underestimated the effect of wave reflection on PPc and LVMI in both men and women. Thus, as compared with relations between indexes of aortic pressure augmentation and PPc or LVMI, strikingly better relations are noted between aortic wave reflection and PPc or LVMI.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司